Table 9-5 Cable net; omparison <strong>of</strong> test case results.<br />

Flat Cable Net Test Case Results<br />

StructureDesigner<br />

Space Gass<br />

Deflection criteria L/51 L/50<br />

Deflection (in) 7.04 7.08<br />

Max cable force (kips) 18.55 18.61<br />

As noted in Chapter 7, the analytical engine used in StructureDesigner for cable net<br />

structures (DR) is not an approximation method but provides an exact element in the same<br />

manner as Space Gass. Thus the results, as can be seen in Table 9-5, are nearly identical.<br />

The tool certainly requires additional testing, but the core methodology as derived from DR,<br />

a program that has been used by many people on many projects for over a decade, is<br />

proven, accurate and reliable.<br />