<strong>DOE</strong>-<strong>STD</strong>-I090-<strong>96</strong> (Rev-I)4. Corroded or broken wires at endconnections.5. Corroded, cracked, bent, worn, orimproperly applied end connections.6. Kinking, crushing, cutting, orunstr<strong>and</strong>ing.b. The qualified inspector shall take care wheninspecting running rope where rapid deteriorationcould occur, such as in the following:1. Sections in contact with saddles,equalizer sheaves, or other sheaves where ropetravel is limited.2. Sections ofthe rope at or near terminalends where corroded or broken wires mayprotrude.c. The qualified inspector shall take care wheninspecting certain ropes such as the following:1. Rotation-resistant ropes, because oftheir higher susceptibility to damage. The internaldeterioration ofrotation-resistant ropes may notbe readily observable.2. Boomhoist ropes, because ofthedifficulty ofinspection <strong>and</strong> the important nature ofthese ropes.d· No precise rules can begiven fordetermining the exact time to replace wire ropebecause many variables are involved. Safety inthis respect depends largely on the use ofgoodjudgment by an appointed person in evaluatingremaining strength in a used rope, after allowancefor deterioration disclosed by inspection. Safetyofrope operation depends on this remainingstrength.e. Conditions such as the following shall besufficient reason for questioning rope safety <strong>and</strong>considering replacement:1. In running ropes, six r<strong>and</strong>omlydistributed broken wires in one rope lay, or threebroken wires in one str<strong>and</strong> in one rope lay.2. In st<strong>and</strong>ing ropes, more than twobroken wires in one lay in sections beyond endconnections or more than one broken wire at anend connection.3. In rotation resistant ropes, twor<strong>and</strong>omly distributed broken wires in six ropediameters or four r<strong>and</strong>omly distributed brokenwires in thirty rope diameters.4. One outer wire broken at the point ofcontact with the core ofthe rope that has workedits way out ofthe rope structure <strong>and</strong> protrudes orloops out from the rope structure; additionalinspection ofthis section is required.5. Wear ofone-third the original diameterofoutside individual wires.6. Kinking, crushing, birdcaging, or anyother damage resulting in distortion ofthe ropestructure.7. Evidence ofheat damage from anycause.8. Reduction from nominal diametergreater than those listed in Table 15-1.f. All rope thathas been idle for a month ormore due to shutdown or storage of a crane onwhich it is installed shall be inspected before it isplaced in service. This inspection shall be for alltypes of deterioration <strong>and</strong> shall be performed byan appointed person whose approval shall berequired before further use ofthe rope. A written<strong>and</strong> dated report ofthe rope condition shall befiled.g. To establish data as a basis for judging theproper time for replacement, maintain acontinuing inspection record covering the pointsofdeterioration listed above.h. Ensure that replacement rope is the samesize, grade, <strong>and</strong> construction as recommended bythe crane manufacturer, unless otherwiserecommended by a rope or crane manufacturer dueto actual working condition requirements.i. Never use discarded rope for slings.15.4.2.5.7 Load Hooks/Load Blocks.Load hookslload blocks that have beenchanged-out shall be inspected by a qualifiedinspector before the crane is returned to service.Inspection records shall be retained throughout theservice life ofthe hook or load block <strong>and</strong> shall bereadily available.Chapter 15Construction <strong>Hoisting</strong> <strong>and</strong> <strong>Rigging</strong>Equipment Requirements 15-12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!