PROJECT MANUAL Specifications Seafood Removal Walmart Store No 1186 Liberty TX
Specs - Home
Specs - Home
- No tags were found...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
UniSpec II- <strong>Store</strong> Planning 032610<br />
[]SECTION 03362 – BURNISHED CONCRETE FLOOR FINISHES<br />
PART 1 - GENERAL<br />
1.1 SUMMARY<br />
A. Section Includes:<br />
1. Application of densifier and protective surface treatment and burnishing of concrete floor slabs.<br />
2. Application of color-tinted densifier as required to tint new slab panels to match existing adjacent concrete<br />
panels.<br />
B. Related Sections:<br />
1. Section 03312- Cast-In-Place Concrete Slabs (Interior). Concrete for interior slabs on grade.<br />
2. Section 03361- Color Textured (Stamped) Concrete Finishes.<br />
1.2 SUBMITTALS<br />
A. Section 01330 - Submittal Procedures: Procedures for Submittals.<br />
B. Submit to Architect specified in Section 01330 and to the Wal-Mart Construction Testing Laboratory specified in<br />
Section 01458.<br />
C. Product Data:<br />
1. Densifier: Brand name, chemical composition, installation directions and certificates of compliance with<br />
required standards. Submit 30 days prior to first concrete placement.<br />
2. Protective Treatment: Brand name, chemical composition, installation directions and certificates of<br />
compliance with required standards. Submit 30 days prior to first concrete placement.<br />
3. Burnishing Pads: Submit product data for burnishing pads prior to beginning burnishing operations to<br />
verify pad texture.<br />
D. Applicator Qualifications:<br />
1. Provide list of a minimum of 5 projects performed within the last 3 years of similar type, size and<br />
complexity as this contract.<br />
2. Provide documentation showing densifier and protective treatment applicator is certified by the densifier<br />
manufacturer.<br />
a. Letter shall be from the product manufacturer stating that the installer is qualified and certified<br />
by the manufacturer to install the material to be used, citing the specific project and location.<br />
3. Submit 30 days prior to first concrete placement.<br />
E. Provide name of technically qualified densifier manufacturer’s field representative.<br />
1.3 QUALITY ASSURANCE<br />
A. Regulatory Requirements:<br />
1. Accessibility Requirements: Comply with applicable requirements of the Americans with Disabilities Act<br />
Accessibility Guidelines (ADAAGs) for Buildings and Facilities; Final Guidelines, revisions, and updates<br />
for static coefficient of friction for walkway surfaces.<br />
B. Environmental Requirements:<br />
1. Comply with current Federal and local toxicity and air quality regulations and with Federal requirements on<br />
content of lead, mercury, and other heavy metals. Do not use solvents in floor polish products that<br />
contribute to air pollution.<br />
03362-1<br />
<strong>Walmart</strong> #<strong>1186</strong> – <strong>Liberty</strong>, <strong>TX</strong> 04/20/11<br />
CMA/10118.034