PROJECT MANUAL Specifications Seafood Removal Walmart Store No 1186 Liberty TX
Specs - Home
Specs - Home
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
guard against defects and deficiencies and substantiate that proposed construction will substantially comply with<br />
construction documents.<br />
D. Quality Control: Tests, inspections, procedures, and related actions during and after execution of the Work to<br />
evaluate that actual products incorporated into the Work and completed construction substantially comply with<br />
construction documents.<br />
E. Quality assurance and quality control may be performed by either the Contractor or the Construction Testing<br />
Laboratory employed by the Owner.<br />
F. Construction Testing Laboratory (CTL): The independent testing and inspection agency employed by the Owner.<br />
G. Architect of Record (AOR): The prime consultant in charge of overall design and coordination of the building.<br />
H. Engineer of Record (EOR): The Registered Engineer in responsible charge of engineering design for the project.<br />
I. Structural Engineer of Record (SER): The Registered Engineer in responsible charge of the structural design for<br />
the project.<br />
J. Civil Engineering Consultant (CEC): The Registered Engineer in responsible charge of the civil design for the<br />
project.<br />
K. Architect - Engineer (A/E): A collective term to include the AOR, CEC, SER, and the Mechanical, Electrical, and<br />
Fire Protection EOR.<br />
L. Special Inspector (SI): The Special Inspector under the direct supervision of a registered civil/structural engineer<br />
(unless otherwise specified) regularly engaged in inspection, and experienced with the type of work requiring<br />
related testing and inspection. The categories of special inspector are:<br />
1. Technical I (TI): A Technician who is an employee of a qualified and approved testing laboratory. Lab<br />
work shall be performed in a qualified testing laboratory.<br />
2. Technical II (TII): A Technician with a minimum of 2 years experience, or a graduate engineer, and is an<br />
employee of a qualified and approved testing laboratory.<br />
3. Technical III (TIII): An engineer regularly engaged in related work with a minimum of 4 years of<br />
experience, licensed in the State in which the project is located, and is an employee of a qualified and<br />
approved testing laboratory. This licensed engineer shall review and approve all final field reports.<br />
4. Structural I (StI): A graduate civil/structural engineer, or other trained and experienced personnel<br />
acceptable to the SER, with experience in the testing and inspection of related structural systems.<br />
5. Structural II (StII): A civil/structural engineer regularly engaged in related work with a minimum of 4 years<br />
of experience, licensed in the State in which the project is located. The licensed engineer shall review and<br />
approve all inspection reports.<br />
6. Independent Roofing Inspector (IRI): A technician employed or subcontracted by the CTL for the purpose<br />
of field observation of roofing installation. The IRI shall be certified as a Registered Roofing Observer<br />
(RRO) by the Institute of Roofing, Waterproofing, and Building Envelope Professionals (RCI) (Formerly<br />
Roof Consultants Institute).<br />
7. Roofing Technician: A technician employed by the CTL with training and experience in roofing<br />
construction or inspection. The Roofing Technician shall be under the direct supervision of the IRI and<br />
shall provide continuous inspection during roofing work.<br />
8. Unique special inspector requirements, for specific materials and system, are noted in related technical<br />
specification sections.<br />
M. Building Official: The Officer or his duly authorized representative charged with the administration and<br />
enforcement of the local building code.<br />
N. Continuous Inspection: The full-time observation of work requiring special inspection by an approved special<br />
inspector who is present in the area where the work is being performed.<br />
01458-2<br />
<strong>Walmart</strong> #<strong>1186</strong> – <strong>Liberty</strong>, <strong>TX</strong> 04/20/11<br />
CMA/10118.034