06.09.2015 Views

PROJECT MANUAL Specifications Seafood Removal Walmart Store No 1186 Liberty TX

Specs - Home

Specs - Home

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2.5 DRAINS, CLEANOUTS, HOSE BIBBS, AND HYDRANTS<br />

A. Subject to compliance with Project requirements, provide drains, cleanouts, hose bibbs, and hydrants of<br />

manufacturers, types, and model numbers as scheduled on the Drawings.<br />

2.6 WATER PIPING SPECIALTIES<br />

A. Subject to compliance with Project requirements, provide piping specialties of manufacturers, types, and model<br />

numbers as indicated on the Plumbing Schedules on the Drawings. Water piping specialties shall include such<br />

items as hose bibbs, hydrants, valves, backflow preventers, vacuum breakers, mixing valves, pressure reducing<br />

(regulating) valves, expansion tanks, water hammer arresters, trap primers, and accessories therefor.<br />

2.7 DRAINAGE PIPING SPECIALTIES<br />

A. Subject to compliance with Project requirements, provide piping specialties of manufacturers, types, and model<br />

numbers as indicated on the Plumbing Schedules on the Drawings. Drainage piping specialties shall include floor<br />

and roof drains, deck drains, cleanouts, and accessories therefor.<br />

2.8 GREASE INTERCEPTORS<br />

A. Provide grease interceptor and associated piping as shown on the drawings and as acceptable to the Authority<br />

Having Jurisdiction. Minimum size shall be as indicated.<br />

B. Standard: ASME A112.14.3 for intercepting and retaining fats, oils, and greases from food-preparation or -<br />

processing wastewater.<br />

2.9 SPECIALTY PLUMBING FIXTURES<br />

A. Subject to compliance with Project requirements, provide specialty plumbing fixtures of manufacturers, types, and<br />

model numbers as scheduled on the Drawings.<br />

2.10 PIPE FREEZE PROTECTION<br />

A. Pipe freeze protection system shall include the following:<br />

1. Parallel circuit heating cable.<br />

2. Transformers.<br />

3. Outdoor ambient thermostat.<br />

4. Junction boxes.<br />

5. Branch circuit wiring and conduit as specified in Section 16100.<br />

6. Other items as necessary to complete system.<br />

B. Components:<br />

1. Heating Cable: Parallel circuit, jacketed cable, self-limiting, 120 volt. Provide XL-Trace as manufactured<br />

by Raychem or equal by Chemelex.<br />

a. Provide minimum 5 watts per lineal foot (or more) as required for specified piping and insulation per<br />

manufacturer's published instructions.<br />

b. Provide termination fittings for direct connection to junction boxes.<br />

2. Junction Boxes: NEMA 5 watertight.<br />

3. Outdoor Ambient Thermostat: Provide thermostat with adjustable contacts. Set contacts to close at 40<br />

degrees F on decreasing temperature.<br />

15100-5<br />

<strong>Walmart</strong> #<strong>1186</strong> - <strong>Liberty</strong>, <strong>TX</strong> 04/20/11<br />

CMA/10118.034

Hooray! Your file is uploaded and ready to be published.

Saved successfully!