06.09.2015 Views

PROJECT MANUAL Specifications Seafood Removal Walmart Store No 1186 Liberty TX

Specs - Home

Specs - Home

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

together.<br />

b. Install optional products specified in Part 2 above in accordance with the manufacturers printed<br />

instructions.<br />

c. Install field-cut runner for solid bridging at each end of wall, adjacent to wall openings, and 10 feet<br />

on center maximum. Install 1-1/2 inch wide, 20 (30 mil) gage strap bracing on both sides of stud.<br />

Fasten strap bracing to each solid bridging runner section with four screws.<br />

2. Gypsum Board Partitions: Space lateral bracing at the following intervals:<br />

a.<br />

b.<br />

c. Provide bracing at ceiling line or at mid-span of studs at areas without ceilings.<br />

3. Wire Mesh Partitions: Space lateral bracing at the following intervals:<br />

a. Stud Length Greater Than 8 Feet and Up To 10 Feet: Provide bracing at midpoint.<br />

b. Stud Length Greater Than 10 Feet and Up To 15 Feet: Provide bracing at third points.<br />

c. Stud Length Greater Than 15 Feet and Up To 20 Feet: Provide bracing at quarter points.<br />

O. Install braced framing of steel stud framing as indicated on Drawings. Use only screw attachments.<br />

P. Blocking: Screw attach wood blocking between studs. Install blocking for support of plumbing fixtures, toilet<br />

partitions, wall cabinets, toilet accessories and hardware.<br />

Q. Framing Fastening: Fasten framing in accordance with manufacturer's published instructions and schedule below,<br />

unless indicated otherwise on Drawings.<br />

CONNECTION<br />

FASTENER<br />

Floor Track to Concrete .................................................................... 1 - Pin at 32 inches on center.<br />

Partition Stud to Floor Track ............................................................ 1 - Screw each side at each flange.<br />

Stud Brace Web to Stud Web ........................................................... 2 - Screws.<br />

Plates and Straps to Studs ................................................................. 2 - Screws.<br />

Stud Web to Stud Web ...................................................................... 2 - Screws.<br />

Stud Brace Web to Attachment Angle .............................................. 2 - Screws.<br />

Lateral Bracing to Partition Stud Using clip Angles ......................... 2 - Screws to stud and 2 - Screws to cold<br />

rolled channel.<br />

Runner to Header .............................................................................. 1 - Screw at 16 inches on center, maximum 6<br />

inches from each end.<br />

3.4 INSTALLATION OF CEILING FRAMING<br />

A. Existing Mezzanine floor joists may be used as the ceiling structure. The Contractor shall screw gypsum board to<br />

floor joist, however it is the Contractor’s responsibility to provide a level ceiling regardless of Mezzanine floor<br />

joist levelness. If required, add blocking to level substrate.<br />

B. For existing steel floor joists supporting Mezzanines, an alternate ceiling framing shall be used.<br />

1. Main Runners: Space main carrying channels perpendicular to steel joists (above) at maximum 48" o.c., not<br />

more than 6" from perimeter walls. Position and level channels to proper ceiling height. Twist end of tie<br />

three full times around hanger, then bend in direction of hanger. Do not allow main runners to come in<br />

contact with abutting walls. Lap splices minimum 12" and secure together 2" from each end of splice with<br />

double loops of 16 gauge tie wire.<br />

2. Furring Channels: Saddle tie furring channels to main runners with two strands of 16 gauge tie wire. Do<br />

not allow furring channels to come in contact with abutting walls. Lap splices minimum 8" and secure<br />

together 1" from each end of splice with double loops of 18 gauge tie wire. Place furring channels<br />

perpendicular to carrying channels at 24" o.c. not more than 2" from perimeter walls.<br />

3.5 INSTALLATION: SUSPENDED CEILING<br />

09250-8<br />

<strong>Walmart</strong> #<strong>1186</strong> – <strong>Liberty</strong>, <strong>TX</strong> 04/20/11<br />