- Page 1 and 2:
1300 Summit Avenue Suite 300 Fort W
- Page 3 and 4:
UniSpecDOCUMENT 00007 - SEALS PAGE
- Page 5 and 6:
SEALS PAGE (Continued) STRUCTURAL E
- Page 8 and 9:
UniSpec II - Store Planning 032610
- Page 10 and 11:
16050 Basic Electrical Materials an
- Page 12 and 13:
A. Limit use of site to allow for:
- Page 14:
UniSpec II - Store Planning 011108
- Page 17 and 18:
A. A $250 administrative cost will
- Page 20 and 21:
UniSpec II- Store Planning 012910 S
- Page 22 and 23:
UniSpec II- Store Planning 090105 S
- Page 24 and 25:
1.4 SCHEDULE UPDATES A. The Contrac
- Page 26 and 27:
1.3 TRANSMITTAL A. Transmit each su
- Page 28 and 29:
UniSpec II- Store Planning 043010 R
- Page 30 and 31:
UniSpec II-Store Planning 111910 SE
- Page 32 and 33:
O. Periodic Inspection: The part-ti
- Page 34 and 35:
samples. Provide lift equipment as
- Page 36 and 37:
Concrete Slabs) 03931 - Existing In
- Page 38 and 39:
UniSpec II- Store Planning 090105 S
- Page 40 and 41:
NEUTRALIZATION ENCLOSURE CERTIFICAT
- Page 42 and 43:
A. Provide, maintain and pay for te
- Page 44 and 45:
3. Office space with desk and chair
- Page 46 and 47:
1.21 SIGNAGE A. Temporary Construct
- Page 48 and 49:
UniSpec II - Store Planning 062609
- Page 50 and 51:
Not Used END OF SECTION 01600-3 Wal
- Page 52 and 53:
D. Remove packaging and clean produ
- Page 54 and 55:
UniSpec II - Store Planning 012811
- Page 56 and 57:
9. The Contractor shall verify exis
- Page 58 and 59:
G. Obtain all required inspections
- Page 60 and 61:
2. Where a product or type of const
- Page 62 and 63:
C. Cleaning materials shall be clea
- Page 64 and 65:
12. Touch up and otherwise repair a
- Page 66 and 67:
K. Re-Use: The use, in the same or
- Page 68 and 69:
G. Supply workers and subcontractor
- Page 70 and 71:
UniSpec II- Store Planning 111910 S
- Page 72 and 73:
a. Elastomeric Membrane Roofing (Se
- Page 74 and 75:
STORE/CLUB TYPE (Check Those That A
- Page 76 and 77:
Rubber: VCT: PVC: Ceramic: R.R. Par
- Page 78 and 79:
[CONTRACTOR’S LETTERHEAD] CONTRAC
- Page 80 and 81:
7. Test soils around buried tanks f
- Page 82 and 83:
3. Storage or sale of removed items
- Page 84 and 85:
3.4 DISPOSAL OF DEMOLISHED MATERIAL
- Page 86 and 87:
UniSpec II-Store Planning 022610 SE
- Page 88 and 89:
E. Contact Wal-Mart Store Planning
- Page 90 and 91:
3.2 INSTALLATION A. Install shoring
- Page 92 and 93:
B. Satisfactory Materials: ASTM D 2
- Page 94 and 95:
A. Classification of Excavation: Th
- Page 96 and 97:
C. Work shall be preformed by a Spe
- Page 98 and 99:
2. ACI 301 - Structural Concrete. 3
- Page 100 and 101:
e. Data indicating chloride ion con
- Page 102 and 103:
1. The concrete floor finishing sub
- Page 104 and 105:
excessive exhaust gases containing
- Page 106 and 107:
2.3 FORMWORK: A. Forms: 1. Plywood,
- Page 108 and 109:
A. Provide admixture products as sp
- Page 110 and 111:
average times of initial setting. T
- Page 112 and 113:
B. Design, construct, erect, suppor
- Page 114 and 115:
4. Space joints to allow one contin
- Page 116 and 117:
supplementary cementing materials,
- Page 118 and 119:
4. Spread compound evenly using mop
- Page 120 and 121:
sieve analysis of material retained
- Page 122 and 123:
3. Prevention of stored materials i
- Page 124 and 125:
C. MIX DESIGN Cement Coarse Aggrega
- Page 126 and 127:
CONTRACTOR'S QUALIFICATION STATEMEN
- Page 128 and 129:
TABLE A TESTING AND INSPECTION SCHE
- Page 130 and 131:
03312-34 Walmart #1186 - Liberty, T
- Page 132 and 133:
2. Limit and control damage from no
- Page 134 and 135:
2.4 EQUIPMENT A. Scrubber Machines
- Page 136 and 137:
3.6 FINISH REQUIREMENTS: A. Gloss:
- Page 138 and 139:
UniSpec II - Store Planning 073109
- Page 140 and 141:
1. Comply with current Federal and
- Page 142 and 143:
2. American Decorative Concrete (80
- Page 144 and 145:
1. Pentra-Guard (HP) by Convergent
- Page 146 and 147:
E. Continue burnishing operations u
- Page 148 and 149:
UniSpec II- Store Planning 073109 [
- Page 150 and 151:
3. Notify Walmart Concrete Consulta
- Page 152 and 153:
A. Concrete lithium based chemical
- Page 154 and 155:
E. Continue burnishing operations u
- Page 156 and 157:
UniSpec II- Store Planning 022610 S
- Page 158 and 159:
E. Galvanized Steel Sheets: 1. Stru
- Page 160 and 161:
H. Interior Stainless Steel Bollard
- Page 162 and 163:
F. Finish: Embossed. G. Color: Prov
- Page 164 and 165:
UniSpec II - Store Planning 092410
- Page 166 and 167:
2. In joints where plumbing fixture
- Page 168 and 169:
2. Unless noted otherwise, use poly
- Page 170 and 171:
INTERIOR JOINTS MATERIAL TO MATERIA
- Page 172 and 173:
UniSpec II - Store Planning 092410
- Page 174 and 175:
3.2 INSTALLATION (BY CONTRACTOR) A.
- Page 176 and 177:
C. Gypsum Association (GA): 1. GA-2
- Page 178 and 179:
N. Flat Straps and Plates: ASTM A 6
- Page 180 and 181:
. Substitutions not permitted. 2. E
- Page 182 and 183:
together. b. Install optional produ
- Page 184 and 185:
3.9 INSTALLATION - GYPSUM BOARD A.
- Page 186 and 187:
items installed within framing. 3.1
- Page 188 and 189:
PART 2 - PRODUCTS 2.1 MANUFACTURERS
- Page 190 and 191:
E. Locate system on room axis accor
- Page 192 and 193:
f. Kencove vinyl: No. KC213 Granite
- Page 194 and 195:
UniSpec II - Store Planning 092410
- Page 196 and 197:
2.2 MATERIALS A. Paint: Wal-Mart an
- Page 198 and 199:
3.4 MECHANICAL AND ELECTRICAL EQUIP
- Page 200 and 201:
3.9 PAINT SHEEN SCHEDULE A. Gloss:
- Page 202 and 203:
tion) Concrete Masonry Unit (Previo
- Page 204 and 205:
A. Plastic: 1. Clear Plastic: a. Sp
- Page 206 and 207:
UniSpec II - Store Planning 032709
- Page 208 and 209: 2. If the Contractor subcontracts t
- Page 210 and 211: PART 2 - PRODUCTS 2.1 ENERGY MANAGE
- Page 212 and 213: I. Cable: 1. Provide communication
- Page 214 and 215: 13810-9 Walmart #1186 - Liberty, TX
- Page 216 and 217: WAL-MART SUPPORT INSTALLATION FORM
- Page 218 and 219: PRE-CHECKOUT VERIFICATION FORM HOA
- Page 220 and 221: HVAC INFORMATION Rtu # Cool Stage H
- Page 222 and 223: CUTLER HAMMER MODULE CONFIGURATIONS
- Page 224 and 225: PULSE METER LETTER Cutler-Hammer IQ
- Page 226 and 227: OPERATING INFORMATION Communication
- Page 228 and 229: UniSpec II-Store Planning 052209 SE
- Page 230 and 231: 3.3 SCHEDULES: Schedules below appl
- Page 232 and 233: UniSpec II-Store Planning 123010 SE
- Page 234 and 235: 3) Coupling Housings: Ductile iron
- Page 236 and 237: 2.5 DRAINS, CLEANOUTS, HOSE BIBBS,
- Page 238 and 239: E. Install Y-pattern strainers for
- Page 240 and 241: B. Contractor Qualifications: Testi
- Page 242 and 243: G. Report: 1. Provide summary repor
- Page 244 and 245: UniSpec II-Store Planning 022511 SE
- Page 246 and 247: B. Make an inspection of installed
- Page 248 and 249: D. As equipment is received, Refrig
- Page 250 and 251: C. Make joints with use of brazing
- Page 252 and 253: B. Do not endanger any work by cutt
- Page 254 and 255: 15600-11 Walmart #1186 - Liberty, T
- Page 256 and 257: UniSpec II-Store Planning 032511 SE
- Page 260 and 261: UniSpec II-Store Planning 022511 SE
- Page 262 and 263: D. Duct Wrap: ASTM C553. 1. Materia
- Page 264 and 265: B. Substitutions: Not permitted. 2.
- Page 266 and 267: 3.8 SCHEDULES SCHEDULE I - DUCT SUP
- Page 268 and 269: UniSpec II-Store Planning 082106 SE
- Page 270 and 271: 3.3 TESTING A. Upon completion of i
- Page 272 and 273: UniSpec II-Store Planning 032610 SE
- Page 274 and 275: 2.3 OUTLET BOXES AND CONDUIT FITTIN
- Page 276 and 277: 9. GFCI Duplex Receptacle 20A 125V
- Page 278 and 279: 7. Single Locking Receptacle 30A 12
- Page 280 and 281: 2. Plug 20A 250V 2 Pole 3 Wire Grou
- Page 282 and 283: I. Pin & Sleeve - Insulated Water T
- Page 284 and 285: 3. If tank and tank indicators are
- Page 286 and 287: UniSpec II-Store Planning 032610 SE
- Page 288 and 289: UniSpec II-Store Planning 090105 SE
- Page 290 and 291: UniSpec II-Store Planning 012811 SE