15.03.2018 Views

BAKER HUGHES - Drilling Fluids Reference Manual

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Water Based <strong>Drilling</strong> <strong>Fluids</strong><br />

Elastomer Testing<br />

The following elastomer tests (Table 3-20 Effects of AQUA-COL ® and AQUA-COL ® D on<br />

Elastomers in a 5% Solution) show the effect of AQUA-COL ® and AQUA-COL ® D on<br />

elastomers in a 5% solution.<br />

Table 3-20<br />

Effects of AQUA-COL ® and AQUA-COL ® D on Elastomers in a 5% Solution<br />

Product Elastomer Time (hrs) Temp (°F) Volume<br />

Change %<br />

Hardness<br />

Change %<br />

AQUA-COL ® Type D 72 250 5.92 5.3<br />

AQUA-COL D ® Type D 72 250 7.50 6.3<br />

AQUA-COL ® Type F 72 250 5.44 4.0<br />

Engineering Guidelines and Comments<br />

Premixed Fluid<br />

North Sea<br />

An existing practice in the North Sea has typically been to utilize concentrated premixes of<br />

AQUA-COL ® to cut down on the number of drums of glycol required at the rig-site and then to<br />

maintain glycol levels at 3% to 5% while drilling. A glycol premix has typically contained 80<br />

lbm/bbl KCl, 7% AQUA-COL ® and 5 lbm/bbl MIL-PAC ® LV. Laboratory tests were conducted<br />

which showed that this mixture produced a cloud point of 6°C (43°F) with complete phase<br />

separation at 8°C (47°F).<br />

Further cloud point measurements have been made to determine the highest levels of KCl and<br />

AQUA-COL ® which could be combined without the risk of phase separation under normal<br />

operating conditions. If the same ratio of salt to glycol as in the original premix is to be<br />

maintained, then 60 lbm/bbl KCl and 5.25% AQUA-COL ® will give a cloud point in the region<br />

of 24°C (75°F). This should be adequate unless there is significant heat input to the fluid resulting<br />

from shear during mixing.<br />

If the KCl concentration is reduced to 50 lbm/bbl, this will allow 7% AQUA-COL ® to be added.<br />

This formulation should be used if the primary requirement is to minimize the number of drums<br />

of glycol shipped to the rig. At 70 lbm/bbl KCl, the highest level of AQUA-COL ® which can be<br />

added without the cloud point dropping below 20°C (68°F) is 2%. Premixes containing more than<br />

60 lbm/bbl KCl should not be used in conjunction with AQUA-COL ® .<br />

Gulf of Mexico<br />

The practice of shipping premixed fluid to the rig is becoming more commonplace. The desired<br />

fluid properties for the anticipated interval are established and a suitable volume of liquid is<br />

prepared. After drilling the cement and performing the formation integrity test, the wellbore is<br />

displaced with the AQUA-DRILL ® fluid. A suitable high viscosity spacer of 30 to 50 bbls is<br />

pumped ahead of the AQUA-DRILL ® fluid.<br />

<strong>Reference</strong> <strong>Manual</strong><br />

Baker Hughes <strong>Drilling</strong> <strong>Fluids</strong><br />

3-78 Revised 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!