15.03.2018 Views

BAKER HUGHES - Drilling Fluids Reference Manual

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Contamination of Water Based <strong>Fluids</strong><br />

Therefore, M f values in excess of five (5) may be indicative of carbonate and bicarbonate anions<br />

or could be caused from a highly treated lignosulfonate/lignite fluid as well.<br />

Figure 4-2<br />

Ions Present at Various pH Levels<br />

11.4<br />

pH<br />

OH¯<br />

or<br />

OH¯ and CO 3<br />

=<br />

Filtrate pH<br />

8.3<br />

OH¯<br />

or<br />

OH¯ and CO 3 =<br />

or<br />

CO 3 = and HCO 3¯<br />

P f<br />

ml<br />

0.02N<br />

H 2SO 4<br />

4.3<br />

HCO 3 ¯ and CO 2<br />

Interfering ions<br />

CO 2<br />

The common alkalinity producing ions which can be present at various pH levels are shown in<br />

Figure 4-2 in relation to the P f and M f alkalinities.<br />

Estimation of Concentration of Carbonates / Bicarbonates<br />

Treatment of carbonates/bicarbonates usually means lime or gypsum and caustic soda additions<br />

and requires a reasonably accurate measurement of CO = 3 /HCO – 3 ions. Over treatment with either<br />

lime or gypsum at a high temperature could lead to temperature flocculation or solidification.<br />

Therefore, caution should be exercised in most cases before treating a CO = 3 /HCO – 3 problem and<br />

treatment amounts should be supported with documented pilot testing. Before treatment can start,<br />

an estimation of the amounts of carbonates in the mud should be made.<br />

The API has standardized three methods for the measurement of carbonates in drilling fluids.<br />

The recommended method is the Garrett Gas Train (GGT) which is the only method of the three<br />

which directly measures carbonates. All other methods use alkalinity data to infer the<br />

concentration of carbonates and bicarbonates in the fluid. The GGT procedure is discussed<br />

briefly in this chapter and a complete description of the test is given in API Bulletin RP 13B-1.<br />

The other two methods are the traditional P f /M f titration and the P1/P2 titration. The P1/P2<br />

method was developed to overcome limitations in the P f /M f method which tends to greatly over<br />

estimate the bicarbonate concentration, particularly in highly buffered systems. The P1/P2<br />

titration uses barium chloride to precipitate barium carbonate. Because barium chloride is<br />

poisonous and because the titrations are very sensitive, caution must be exercised when the<br />

method is used. Figure 4-1 compares the advantages/disadvantages of the two methods.<br />

A fourth alternate mathematical model has been developed using the pH/P f relation to estimate<br />

probable carbonate/bicarbonate concentrations and is illustrated in this chapter.<br />

Baker Hughes <strong>Drilling</strong> <strong>Fluids</strong><br />

<strong>Reference</strong> <strong>Manual</strong><br />

4-8 Revised 2006

Hooray! Your file is uploaded and ready to be published.

Saved successfully!