15.03.2018 Views

BAKER HUGHES - Drilling Fluids Reference Manual

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BOREHOLE PROBLEMS<br />

accelerator is available for cold water applications. X-LINK pills can be used in water, syntheticor<br />

oil-base drilling fluids.<br />

In the event an X-LINK pill is mixed but not pumped, it can be bled back into the active mud<br />

system. If no accelerator is used, there is no danger from gelation in the tank provided retarder<br />

was used in the formula. If an accelerator was used, the pill can be diluted with water to a 1%<br />

solution to eliminate cross-linking.<br />

Once the X-LINK pill sets, it is easily drilled or reamed and can be removed from the mud<br />

system over conventional shale shakers.<br />

Temperature,<br />

ºF<br />

X-LINK,<br />

lbs/bbl<br />

Accelerator,<br />

lbs/bbl<br />

Retarder,<br />

lbs/bbl<br />

Retarder,<br />

gal/bbl<br />

Pumpable<br />

Time, min<br />

Set Time,<br />

min<br />

60 40 0.3 27 90<br />

120 40 0.078 80 150<br />

150 40 5.85 0.53 90 180<br />

200 40 10.4 0.95 90 180<br />

250 40 15.6 1.42 90 180<br />

300 40 17.6 1.60 90 180<br />

Table 7 - 5 Formulation for One (1) Barrel of Un-weighted X-LINK as Function of<br />

Temperature<br />

<strong>BAKER</strong> <strong>HUGHES</strong> DRILLING FLUIDS<br />

REFERENCE MANUAL<br />

REVISION 2006 7-31