10.07.2015 Views

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Ryan</strong> <strong>Herco</strong> Logo-4 Color ProcessElement: Placed Monotone EPSF o nt: Univers BlackMedium: Max size 21”X3.9”C=87, M=13, Y=2, K=1C=0, M=0, Y=0, K=72HANNA INSTRUMENTSpH & ORP CONTROLLERSPanel mount pHcontroller modelHI8710E shownabove.Panel mount pHcontroller modelHI8711E shownabove.500.110.170 AllPANEL MOUNTED pH CONTROLLER — SINGLE SET-POINTFEATURES• Single set point version with selection of acid oralkaline dosage.• The alarm band is user-selectable from 0.1 to 3 pHand will be activated when the pH level deviatesfrom the set point by more than the selected alarmvalue.• When used in conjunction with the HI 8720 ORPORDER INFORMATION:5905.024 PANEL MOUNT SINGLE SET-POINTpH CONTROLLER, 4-20 mA OUTPUT5905.020 PANEL MOUNT SINGLE SET-POINTpH CONTROLLER, 0-20 mA OUTPUTPANEL MOUNTED pH CONTROLLER —DUAL SET-POINTFEATURES• Dual set-point with 2independent dosing outputs,one for acid and another foralkaline dosage.• Auto-diagnostic feature isincorporated to verify offsetand slope calibration as wellas electrode contamination/deterioration.• The alarm band is userselectable from 0.1 to 3 pHand will be activated whenthe pH level deviates fromthe set point by more thanthe selected alarm value.ORDER INFORMATION:5905.124 PANEL MOUNT DUAL SET-POINTpH CONTROLLER, 4-20 mA OUTPUT5905.120 PANEL MOUNT DUAL SET-POINTpH CONTROLLER, 0-20 mA OUTPUTcontroller, ODCD ensures that ORP dosage willonly start when the pH is at the correct level.• Use the direct input from a pH electrode.• Isolated recorder output in either 0 to 20 mA or 4to 20 mA configurations.• Sophisticated auto-diagnostic functions make iteasy to check and troubleshoot malfunctions fromthe front panel.$540.00540.00500.110.160• When used in conjunctionwith the HI 8720 ORPcontroller, ODCD ensuresthat ORP dosage will onlystart when the pH is at thecorrect level.• Use with direct input from apH electrode.• Isolated recorder output ineither 0 to 20 mA or 4-20mA configurations.• Splash proof transparentcover protects the controlsof the instrument fromliquids.$576.00576.00SPECIFICATIONS5905.020, .024, .120 & .124Range0.00 to 14.00 pHResolution0.01 pHAccuracy (@±0.02 pH20°C/68°F)Typical EMC Deviation±0.1 pHInputHigh impedance 10 12 ohmCalibration Offset: ±2 pH by wwO trimmer /Slope: 80 to 110∞ by slopetrimmerTemp. Comp.Fixed or automatic with pt100from 0 to 100°C (32 to 212°F)Readout4-digit LCD plus graphicsymbolsRecorder Output0 to 20 mA or 4 to 20 mA(isolated)Setpoint Relay/ One, isolated, 2 A, Max. 240VAlarm Relay Version resistive load, 1,000,000 strokes(Single Set-Point)Setpoint RelayDual Set-PointVersionAlarm RelayDual Set-PointVersionPower SupplyEnclosureTwo, isolated, 2 A, Max. 240Vresistive load, 1,000,000 strokesOne, isolated, 2 A, Max. 240Vresistive load, 1,000,000 strokes110/115V or 220/240V; 50/60 HzDIN 43 700 144 x 72 mm(5.67 x 2.83”) in black anodizedaluminum. Front and back withshockproof ABS plastic andtranparent cover.Environment14 to 122°F (-10 to 50°C);RH 95% non-condensingWeight/Panel Cutout 2.2 Ib. (1 kg)/5.55 x 2.71”(141 x 69 mm)NOTE: pH electrodes orderedseparately. See page 370 for details.Panel mount ORPcontroller modelHI8720E shownabove.500.110.200PANEL MOUNTED ORP CONTROLLERFEATURES• Single set point version withselection of reducing oroxidizing dosage.• Automatic diagnosticcontrols can be useractivated to check 0 mV andoffset status.• The alarm band is userselectablefrom 10 to 200mV and will be activatedwhen the mV level deviatesfrom the set point by moreORDER INFORMATION:5905.224 PANEL MOUNT ORP CONTROLLER,4-20 mA OUTPUT5905.220 PANEL MOUNT ORP CONTROLLER,0-20 mA OUTPUTthan the selected alarmvalue.• When linked to the consentcontacts of the HI 8710 (seeabove) pH controller, PDCDensures that ORP dosingwill start only when the pHlevel is corrected.• Use with direct input froman ORP electrode.• Isolated recorder output ineither 0 to 20 mA or 4 to 20mA configurations.NOTE: ORP electrodes ordered separately.See page 370 for details.$540.00540.00SPECIFICATIONSRangeResolutionAccuracy (@20°C/68°F)Typical EMC DeviationInputCalibrationReadoutRecorder OutputSetpoint Relay/Alarm RelayPower SupplyEnclosure5905.220, & .224-1000 to 1000 mV1 mV±5 mV±6 mVHigh impedance 10 12 ohmSlope: 90 to 110% byslope trimmer4-digit LCD plus graphicsymbols0 to 20 mA (5905-220) or4 to 20 mA (5905-224)(isolated)One, isolated, 2 A, Max. 240Vresistive load, 1,000,000strokes110/115V or 220/240V; 50/60 HzDIN 43 700 144 x 72 mm(5.67 x 2.83”) in black anodizedaluminum. Front and back withshockproof ABS plastic andtranparent cover.Environment14 to 122°F (-10 to 50°C);RH 95% non-condensingWeight/Panel Cutout 2.2 Ib. (1 kg)/5.55 x 2.71”(141 x 69 mm)360

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!