10.07.2015 Views

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Ryan</strong> <strong>Herco</strong> Logo-4 Color ProcessElement: Placed Monotone EPSF o nt: Univers BlackMedium: Max size 21”X3.9”C=87, M=13, Y=2, K=1C=0, M=0, Y=0, K=72SENSOREX SELF-CLEANINGpH & ORP ELECTRODESPREAMPLIFIERSAll pH meters have a preamp to which the electrode connects.Most often, this is either built into the meter, or providedas a separate field located unit. In many of these cases, theSensoreX electrodes can be connected directly to the unit.When the original equipment preamp cannot be accessed, aSensoreX preamp will be needed. This is the case when thepreamp is built into the “disposable” electrode. The new preampis a one-time purchase, and will permit you to use the lower costprobes for all future replacements, saving money. See preampguide below.FEATURES• Flat surface solves coatingproblems.• Resists abrasion fromslurries.• Reduces maintenance anddowntime.• Saves time and money.• Select from four differentmounting configurations:submersion, inline,insertion-wet-tap, and bypass.• Flat surface pH and ORPelectrodes from SensoreXcan be used as directreplacement electrodesfor most every make andmodel controller.• They can be supplied withor without temperaturecompensated mountinghardware.• CPVC and PVDF (Kynar)materials of constructionare available.• Special versions forHydrofluoric acid, electricalground loops, low ionicsolutions, and continuoushigh temperature use areavailable.• Thequick-disconnectcartridge design permitsthe electrode to be removedin seconds for cleaningwithout the need for tools.TEMPERATURE COMPENSATIONThe output of a pH electrode varies with temperature in amanner predicted by theory. The real need for ATC dependsupon the temperature variation, the pH value being measured,and the desired measurement accuracy. Most customers willNOT require ATC to obtain accurate results. When needed,SensoreX will build automatic temperature compensators(ATC) into the electrode holders. For example, a waste waterapplication with pH varying between 5 and 9 and temperaturevarying between 5° C and 45° C will have a maximum errorof only 0.12 pH. If the needed accuracy is 0.5 pH, then ATCis not needed. If on the other hand, a process liquid pH variesbetween 3 to 11 and the temperature varies between 25° C to75° C, the error is 0.6 pH , and ATC is probably needed.When ATC is not needed, the meter should be placed into themanual temperature compensation position. If the meter doesnot have this switch, a simple fixed resistor equal in value to theresistance of the meter’s ATC should be installed across thetemperature compensators terminals.When ATC is required, the necessary temperature element willbe built into the electrode holder. It will be necessary to specifythe make and model number of your meter-controller so that thecorrect ATC element will be incorporated into the electrode holder.AUTOMATIC TEMPERATURE COMPENSATOR (ATC), PREAMPLIFIER GUIDE(A)ORIGINAL pH METERMFG./MODELAuto Temp Comps ForOriginal Equipment(B)Ohmsat 25° C(C)Temp. Comp.Suffix(D)SensorexPreamplifiersModelAuto Temp Comps ForSensorex Preamplifier(E)Ohmsat 25° C(F)Temp. Comp.SuffixFoxboro, 870, 872, 873, 874 110 -PT1 V2 3000 -UNSGreat Lakes, 60, 70 300 -GLI V1 3000 -UNSGreat Lakes, 90, 95, 570,671, 672, 690, P33, P53, P63 300 -GLI GL90A 300 -GLIL & N, 7073, 7075 721 -LN7 V1 3000 -UNSL & N, 7076, 7079 721 -LN7 V1-LN 3000 -UNSL & N, 7082, 7083, 7084, 9782 8500 -LN8 V1 3000 -UNSLMI DP5000 1000 P1K PHAMP-1 1000 P1KYokogawa pH200, pH400 1000 P1K PHAMP-1 1000 P1KRosemount/Uniloc, 1050, 1181 3000 -UNS U2587 3000 -UNSRosemount, 1054, 1054A,1055, 54 110 -PT1 U698-03 110 PT1Rosemount: 2081, 3081 110 -PT1 SDI/EC1 3000 -UNSNOTE: Contact <strong>Ryan</strong> <strong>Herco</strong> <strong>Flow</strong> <strong>Solutions</strong> if your meter does not appear in the above chart.SPECIFICATIONS• pH range: 0-14 (12.3 without Na+error).• Response: 95% within 5 seconds.• Wetted materials: CPVC, HDPE, Viton,pH glass, EPR, PVDF, pH glass.• Temperature/ pressure ratings:50-170°F(10°-76°C)/100 psig; 50°-180°F (10°-81°C)/85 psig; 50°-212°F(10-100°C)/50psig.NOTE: For constant use at temperaturesabove 170°F, please order special hightemperature electrode.POPULAR UNBREAKABLE EPOXY BODY pH AND ORP ELECTRODESORDER: 5910.(Size No.) EPOXY pH ELECTRODE(includes 30” cable, BNC connector and soaker cap or bottle)Size No. Sensorex Model Number Type Size (mm) Price Each663 S200C-BNC General Use pH 12 dia. x 150L $52.00665 S200CD-BNC Double Junction pH 12 dia. x 150L 63.00666 S300C-BNC Long and Thin 9 dia. x 300L 75.00668 450C-BNC Flat Surface pH 15 dia. x 115L 73.00658 S500C-ORP-BNC General Use pH 12 dia. x 150L 78.00Other connectors are available upon request at an additional cost.500.130.110366

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!