10.07.2015 Views

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Ryan</strong> <strong>Herco</strong> Logo-4 Color ProcessElement: Placed Monotone EPSF o nt: Univers BlackMedium: Max size 21”X3.9”C=87, M=13, Y=2, K=1C=0, M=0, Y=0, K=72FLOWLINE LEVEL CONTROLLERSDATALOOP INTRINSICALLY SAFE METERFEATURES• Offered in intrinsically safe and generalpurpose configurations.• Large 5 digit LCD main display withsecondary unit and bar graph display.• Intuitive push button menu makesconfiguration fast and easy.• I/8 DIN enclosure with NEMA 4Xfaceplate and shallow depth case.• Linear, square root and programmableexponent functions.• Non-volatile memory ensures programand set point retention.• Accessory NEMA 4X windowedenclosure for field installation.SPECIFICATIONS• Display:Type: LCD, 5-digitUnits: EngineeringDecimal Point: FloatingOutput: -99999 to 999999Height:Backlight:• User interface:• Sensor Input:• Loop Power:• Memory:NRTL/C®0.6” (15 mm)LED, bright orangeFour push button(1) 4-20 mA transmitter12-30 VDCNon-volatile• Voltage drop: 2.0 VDC w/o backlight5.7 VDC w/ backlight• Ambient temp.: F: -22° to 149°C: -30° to 65°• EnclosureType: 1/8 DIN, panel mountRating: NEMA 4X (IP65)faceplateMaterial: Polycarbonate• Classification: LI25-2001:Intrinsically safeLI25-1001: Generalpurpose• Approvals: FM; CSA: Class I,Div. I, Groups A, B, C,D; Class II, Div I,Groups E, F, G; ClassIII, Div I; Class I, Zone0, Group IIC; T-code -T4ORDER: 6906.(Size No.) INTRINSICALLY SAFE METERSelect the Configuration and OutputSize No.ConfigurationModelPrice Each023 General Purpose LI25-1001 $325.00024 Intriniscally Safe LI25-2001 525.00765.220.163DATAVIEW METER WITH RELAYSFEATURES• Bright 6-digit LED main display andsecondary unit display with relay statusindicators.• 1/8 DIN enclosure with NEMA 4Xfaceplate and shallow depth case.• 32-point linearization function forvolumetric tank measurement.• Non-volatile memory with securitypassword protected lock out.• Isolated 4-20 mA repeater output with40 mA internal power supply.SPECIFICATIONS• Display:Type: LCD, 6-digitUnits: EngineeringDecimal Point: FloatingOutput: -99999 to 999999Height: Main: 0.6” (15 mm)Second: 0.46” (12 mm)ORDER: 6906.(Size No.) INTRINSICALLY SAFE METER• LED indication: Relay status• User interface: Four push button• Linearization: 2-32 point function• Memory: Non-volatile• Sensor Input: (1) 4-20 mA or 0-10VDC transmitterSelect the Configuration and OutputSize No.ConfigurationModelPrice Each653 Meter only LI55-1001 $485.00654 4-20 mA LI55-1011 585.00655 2 relays LI55-1201 550.00656 2 relays, 4-20 mA LI55-1211 660.00657 4 relays LI55-1401 645.00658 4 relays, 4-20 mA LI55-1411 725.00• Supply Voltage: 85-265 VAC @ 50-60 Hz• Consumption: 20 watts max.• Sensor supply: 24 VDC ±5% @ 200 mA• Repeater output: 4-20 mA, 24 VDC ±5%@ 40 mA• Contact type: 12_1: (2) SPDT (Form C)14_1: (4) SPDT (Form C)• Contact rating: 3A @ 30 VDC or 250VAC resistive load• Ambient temp.: F: -40° to 149°C: -40° to 65°• EnclosureType: 1/8 DIN, panel mountRating: NEMA 4X (IP65)faceplateMaterial: Polycarbonate• Compliance: CE: EN61010-1:2001• Classification: General purpose• Approvals: cULus, UL508765.220.166390

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!