10.07.2015 Views

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CORROSION-RESISTANT FLOATINGSENSORS FOR TANK LEVEL CONTROLSINGLE- & MULTIPLE-POINT LEVELSENSING WITH SINGLE FLOATFEATURES• These liquid-level sensorsprovide simple, troublefreeliquid-level control.The switch is housed insmooth, chemical-resistantthermoplastic casing and issuspended on its own cable.As the fluid level rises, thesensor tilts, and the switchcloses to start or stop apump, open or close a valveor actuate indicator lights asrequired. These sensors areeasy to install—they workeven in solids and scum.• Operates in almost anyliquid.SINGLE-LEVEL• Multiple-level switches inone device.• Overcomes turbulenceeffects.• Immune to adverseenvironment.• No fixtures needed in tanksides.• Simplifies control circuitrywith different versions.• Switching levels easilyadjusted.• Simple to install.• Requires no maintenance.• Low-cost, proven reliability.• These switches work equallyas well with valves as theydo with pumps.Standard series shown above with new mini series level sensors.HOW IT WORKS: The floating switch follows the liquid-levelmovement. As the level varies, the float inclination changes toactuate switches encapsulated in the Polypropylene cone. Wesupply 16 feet of connection cable standard.High-level alarmLow-level alarm.ORDER INFORMATION:6902.100 SINGLE-LEVEL SENSOR (1H), normally open,as shown in High-Level Alarm drawing. Contacts closeas liquid level rises.6902.150 SINGLE-LEVEL SENSOR (1L), normally closed,as shown in Low-Level Alarm drawing. Contacts openas liquid level rises.$108.69108.69* Weight is not needed (and not included) with single-level sensors.SPECIFICATIONS• Contact rating: Max. voltage - 250 VAC or VDC; Max. ACcurrent - (Resistive): 6A; (Inductive): 3A.Max. DC Power: 75VA (0.3A @ 250V).• Max. Liquid temperature: 60°C (140°F).• Max. Pressure (at 20°C): 28 PSI.• Min. fluid specific gravity: 0.7.• Standard cable length: 16’.• Switching differential: Min: 10”; Max: 50”.• Max. no. of switching levels: 4.• Max. no of wires in cable: 6.765.170.110 All”MINI” SINGLE-LEVEL SENSORS• New mini-series singlelevelsensors have thesame electrical capabilitiesas standard series shownabove. Smaller footprintallows use in more diverseapplications or where spaceis limited.ORDER INFORMATION:6902.101 MINI SINGLE- $83.88LEVEL SENSOR(M1H), normallyopenContacts close as liquid levelrises. As shown in high levelalarm drawing above.6902.151 MINI SINGLE- $83.88LEVEL SENSOR(M1L), normallyclosedContacts open as liquid levelrises as shown in low levelalarm drawing above.Mini series.765.170.1201-800-848-1141www.rhfs.com403

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!