10.07.2015 Views

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Ryan</strong> <strong>Herco</strong> Logo-4 Color ProcessElement: Placed Monotone EPSF o nt: Univers BlackMedium: Max size 21”X3.9”C=87, M=13, Y=2, K=1C=0, M=0, Y=0, K=72WEBSTER SEAL-LESS VERTICALCENTRIFUGAL PUMPSSIMPLE INSTALLATIONThese Webster pumps are designed to have the wetend immersed in the fluid being pumped, so that it is notnecessary to prime before pumping. If you desire, you canmount Webster outside the tank as shown below. Care mustbe taken to mount the pump so that the motor is never belowthe maximum liquid level in the tank. This will insure againstaccidental motor flooding. Once it has begun pumping,Webster can lift water up to eight feet, making it an excellentpump for circulating or emptying liquids in deeper tanks.Install in tank. Eliminate loss of expensivesolutions or precious metals. Great forfiltration or carbon treating.Extend inlet for deeper tanks. Simplyclamp adapter plate to side of tank andturn on. You can pump down to bottomof inlet extension.A BETTER WAY• Run it dry if you wish (or if someone goofs). You can’t damagethe pump when this accidentally happens. Nor will you damagethe pump by continuous operation against a shutoff discharge.• No maintenance of mechanical seals or shaft bearings—thereare none. These pumps will even handle slightly abrasivesolutions.• Optimum, corrosion resistance is just one of the qualities of theseWebster pumps constructed of CPVC, PVDF or Polypropylene.No metals contact the solution being pumped.• No seals: The seal-less design eliminates a major problem areafor most pumps. There are no seals to wear out, meaning noleakage of expensive chemicals.• Webster pumps are equipped with totally enclosed motors, andthe baked epoxy painted motor enclosures are standard on allmodels. The motors are equipped with sealed ball bearingsand designed for continuous duty. The single-phase motorsare standard with automatic thermal overload protection, whilethe S2-S16 motors are dual-speed and dual-Hz. Refer to thespecifications for electrical characteristics.Install outside of tank and save neededspace. Ideal for mounting alongsidesump of fume scrubber to recirculatespray solutions.DIMENSIONSMODEL A B C D E F G H I J L M ND1 Series 16-3/32 5-5/16 7/16 7-27/32 3-15/16 3/4” MPT 6-3/16 4 2 2-1/8 4-3/16 1/2” FPT 13/16DD1 Series 17-3/8 5-5/16 7/16 9-3/16 3-15/16 1” MPT 6-3/16 4 2 2-11/32 4-3/16 1/2” FPT 1-5/32S2 Series 21-5/8 8-3/8 1/2 10-7/32 6-1/2 1” MPT 6-7/32 6-7/32 3-7/64 2-1/4 3-7/64 3/4” FPT 1-5/32S4, S5 Series 22-3/4 9-7/8 1/2 9-3/16 6-1/2 1-1/4” MPT 6-7/32 6-7/32 3-7/64 2-7/8 3-7/64 1” FPT 1-3/8SS6, SS7, S8 Series 21-7/32 9-7/8 1/2 7-15/32 6-1/2 1-1/4” MPT 6-7/32 6-7/32 3-7/64 3-7/32 3-7/64 1-1/4” FPT 1-11/16S12 Series 29-1/16 14-1/2 1/2 — 7-3/16 3” Slip 11-7/8 11-7/8 4-31/32 — 6-29/32 1-1/2” FPT 5-5/32S16 Series 30-9/16 15-5/8 1/2 — 9-1/8 3” Slip 11-7/8 11-7/8 4-31/32 — 6-29/32 2” FPT 5-3/8DESIGN FEATURESIMPELLER: D1, DD1, and S2 arestandard with semi-open impellers.All other models are equippedwith closed impellers. The impellerdesign enables continued pumpingwith an inlet extension, evenwhen the fluid level is below thepump volute. The upper impellervanes prevent fluid from risinginside the support column underall discharge conditions, includingshut-in discharge.MOUNTING BRACKET: D1 and DD1 arestandard with the integral mounting bracketof the same material as the pump body. TheS12 and S16 models are equipped with asquare fiberglass mounting plate, dischargeriser and coupling to facilitate installationand to help absorb weight of the added dischargeplumbing.MOUNTING PLATE OR BRACKET Available as an option where notprovided.FUME BARRIER:Webster pumps incorporatea Teflonlip seal to protectthe motor end bellfrom corrosioncaused by fumes orvapor.WEBSTER PUMPSINLET FILTERSCREENFEATURES• 3/16” perforated CPVC screens.• Directly retrofit onto existing inlet fitting.• Easy installation - Just remove retainerring, snap inlet filter into place.• Allows fluids to pass and stops harmfulsolids.660.120.110O-RING: The end cover is sealed with a VitonO-ring, insuring zero leakage when the pump ismounted externally. This is the only non-plasticcomponent in contact with the fluid being pumped.Other elastomers are available upon request.SHAFT: The 303 stainless pump shaft is isolatedfrom the fluid being pumped by a plastic impellersleeve. The sleeve, integral to the impeller, ismade of the same plastic material as the impellerand pump body. Except for the D1 and DD1models, all models utilize a replaceable pumpshaft, allowing for use of a standard electric motorshould a emergency motor replacement beneeded.ORDER INFORMATION:6590.(Size No.) INLET FILTER SCREENSizeNo. Screen Fits Pump SizePriceEach102 DI, DDI, S2 $46.25104 S4, S5 52.05106 SS6, SS7, S8 57.80660.120.900484

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!