10.07.2015 Views

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

27th Edition RHFS Product Guide - Ryan Herco Flow Solutions

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Ryan</strong> <strong>Herco</strong> Logo-4 Color ProcessElement: Placed Monotone EPSF o nt: Univers BlackMedium: Max size 21”X3.9”C=87, M=13, Y=2, K=1C=0, M=0, Y=0, K=72FUJI “PAPERLESS”VIDEOGRAPHIC RECORDERSFuji PHL videographic recorders (Panel mount shown above).Record and view up to 18 channels of data.FEATURES• Economical - Models start under $1,700.00.• Long-term data storage - Up to 1.5 years in compact flash.• Saved data playback - Saved data in memory card can beeasily called out and played back on display.• Math and totalization - These functions are standard.• Communications option - RS485, Modbus RTU protocol.• Screen saver - When period of non-operation exceeds thesetting value of the parameter, the recorder turns off thebacklight of LCD.• PC support software (data viewer/ parameter loader) -Supplied on a CD-ROM as a standard accessory.• Compact size - 6.3” x 5.7” x 7.4” (160x144x185mm) (Panelmount). 3lbs.• 9-Point and 18-point recording - 12 types of thermocouples,5 types of RTD’s and voltage/current input available.• Wide variety of display modes - Trend recording (horizontaland vertical), bar graph, analog meter, digital display,totalized data, historical trend and event summary.• Clock with calendar functions.• Memory back-up.• Full memory and low battery alarms.• 16 MB flash memory card standard.• 9-channel or 18-channel model.• Record up to 12 types of thermocouples, 5 types of RTD’s,and DC voltage/current input on one unit.• PC support software allows you to configure the recorderfrom a PC and view historical data stored on the compactflash card.OPTIONS/ACCESSORY ITEMS• Alarm (relay) output/DI 10SPST relay outputs & inputs.• Alarm (open cell collector)• Alarm output• RS485, Modbus communications.• Long-term data storage - up to 1.5 years in 512 MB compactflash.SPECIFICATIONS• Power supply voltage - 100 to 240VAC, 50/60Hz.• Power consumption - 42VA @ 200VAC.Input• Number of inputs - 9 or 18 points.• Measuring cycles - 100ms/9, 18 points.• Input signal - Thermocouple: B, R, S, K, E, J, T, N, W, L, U,PN. RTD: Pt100, JPt100, Ni100, Pt50, Cu50. DC voltage: 0 to50mV, 0 to 500mV, 0 to 5V or 1 to 5V. DC current: connectingoptional shunt resistor to input terminal.• Input types - Selected from the key panel. The same typemust be set for every 2 channels.• Burn-out function - Equipped for thermocouple and RTDinputs as standard.• Calculation function - Primary delay filter, scaling, calculationof difference between channels, F-value calculation,totalization, and square root extraction.Math Function• Formula - Addition, subtraction, multiplication, division,absolute value, x y , logarithm, natural logarithm, exponentialfunction, humidity, average value, maximum value, minimumvalue.• Input signal - DI (DI1 to DI10), totalize (ch1 to ch30), analoginput (ch1 to ch30), constant (No.1 to No.20), communicationinput (No.1 to No.12).Performance• Indication accuracy - ±(0.15%+1 digit) of input range for allinputs, except ±(0.3%+1 digit) for thermocouple B752 to1112°F (400 to 600°C), thermocouples R and S32 to 572°F(0 to 300°C), and thermocouples K, E, J, T, L and U-328 to-148°F (-200 to -100°C).• Indication resolution - 0.1°F (0.1°C).• Reference junction compensation error - 1.0°F (±0.5°C) forK, E, J, T, N, L, U, PN. 2.0°F (±1.0°C) for R, S, B, W.• Input impedance 1M ohm approximately for thermocoupleand DC voltage.• Maximum input voltage - ±10VDCDisplay• Display - 5.7” TFT color LCD (320 X 240 dots) with backlight,14 colors.• Display contents - Trend display (in vertical and horizontaldirection) selected in the refreshment cycles of 1 sec to12 hours; Scale display/non-display selectable. Bar graphor analog meter display (refresh cycle: 1 second). Digitaldisplay (in refreshment cycle of 1 sec). Event summarydisplay (alarm and message summary). Historical trenddisplay (compact flash memory data). Totalized data display.Group setting (4 groups at the maximum).Alarm Function• Number of settings - Up to 4 alarms are settable for eachchannel.• Indication - Alarm status is displayed on digital display.• Output - 9 points as relay output (option). 18 points as opencollectortransistor output (option).CONTACT YOUR LOCAL<strong>RHFS</strong> SERVICE CENTERFOR MORE INFORMATION1-800-848-1141560.150.110370

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!