Function<br />

Category<br />

RECALL or SAVE<br />

lPAN FS<br />

PSTATE<br />

PURGE<br />

RCLS<br />

RCLT<br />

SAVES<br />

SAVET<br />

SAVRCLF<br />

SAVRCLN<br />

SAVRCLW<br />

STOR’<br />

HNt<br />

HNLOCKt<br />

HNUNLKt<br />

LSPAN<br />

PKZMOK<br />

‘able 5-4. Functional Index (continued)<br />

Comm<strong>and</strong><br />

Corresponding Description<br />

Key Function<br />

SAV LOCK ON OFF Protects all of the spectrum analyzer’s<br />

user state <strong>and</strong> trace registers from bein]<br />

changed.<br />

DELETE FILE Deletes the specified file from the<br />

current mass storage device.<br />

INTERUAL -> STATE Recalls spectrum analyzer state data<br />

from one of the nine state registers in<br />

spectrum analyzer memory.<br />

The softkeys accessed by Recalls previously saved trace data,<br />

Tnternal -> Trace amplitude factors, or limit-line data<br />

from the trace registers in spectrum<br />

analyzer memory.<br />

STATE -> INTRUL Saves the currently displayed<br />

instrument state ln spectrum analyzer<br />

memory.<br />

The softkeys accessed by Saves the selected trace data <strong>and</strong> state<br />

Trace -> Intrnl information, amplitude correction<br />

factors, or limit-line tables in spectrum<br />

analyzer memory.<br />

~or~RECALL] Specifies either a save or recall<br />

operation.<br />

Specifies the number to append to the<br />

prefix for a save or recall operation, am<br />

initiates the transfer of data.<br />

Specilles the data to be transferred.<br />

STATE -> CARD *, Stores data on a RAM card.<br />

Trace -> Card*,<br />

ALL DLP -> CARD *<br />

FULL SPAN Sets the frequency span of the spectrun<br />

analyzer to full span.<br />

Returns the harmonic number of the<br />

current harmonic b<strong>and</strong> in which the<br />

spectrum analyzer is tuning.<br />

B<strong>and</strong> selection accessed by Forces the spectrum analyzer to use<br />

B<strong>and</strong> Luck t or<br />

only the selected harmonic b<strong>and</strong>.<br />

BKD LOCK OR UFFt<br />

BND LOCK OR OFF (OFF is Unlocks the harmonic b<strong>and</strong>.<br />

underlined)+<br />

LAST SPAN Changes the spectrum analyzer’s span tc<br />

the previous span setting.<br />

Returns a “0” if the peak zoom routine<br />

(PKZOOM) found only the spectrum<br />

analyzer’s local oscillator feedthrough,<br />

otherwise a “1” is returned.<br />

PKZOOM PEAK Z#DA Automatically tunes the spectrum<br />

analyzer to the signal with the highest<br />

amplitude level while narrowing the<br />

frequency span to the specified<br />

frequency span.<br />

Option 003 required for <strong>HP</strong> <strong>8590</strong>L or <strong>HP</strong> 8592L.<br />

For <strong>HP</strong> 8592L, <strong>HP</strong> 85933, <strong>HP</strong> 85953, or <strong>HP</strong> 85963 only.<br />

Programming Comm<strong>and</strong>s 5-23