SRCTK<br />

Source Tracking<br />

Adjusts the tracking of the source output with the spectrum analyzer sweep.<br />

Syntax<br />

SRCTK<br />

SRCTK Source Tracking<br />

I t e m Description/Default tinge<br />

Number Any real or integer number. 0 to 16,383.<br />

Option Required: Option 010 or 011.<br />

Equivalent Softkey: Ml? TM ADJUST .<br />

Step Increment: 1.<br />

Related Comm<strong>and</strong>s: Comm<strong>and</strong>s that change b<strong>and</strong>width, such as RB, VB, ST, <strong>and</strong> comm<strong>and</strong>s<br />

that change frequency, such as SP, CF, FA, FB, SP, FS, SRCTKPK.<br />

Example<br />

OUTPUT 718;"MEASURE SR;" Activates the stimulus-response moo%?.<br />

OUTPUT 718;"SRCPWR -2ODB;" Turns on the power at the source output.<br />

OUTPUT 718;"SP IMHZ;" Sets measurement range.<br />

OUTPUT 718;"RB IKHZ;"<br />

OUTPUT 718;"TS;" Zzkes sweep.<br />

OUTPUT 718;"SRCTK EP;" Allows entry offrom front-panel keys to adjust tracking.<br />

Description<br />

The SRCTK comm<strong>and</strong> adjusts the tracking of the tracking-generator output relative to the<br />

center frequency of the spectrum-analyzer. SRCTK is used typically for b<strong>and</strong>widths less than<br />

300 kHz. B<strong>and</strong>widths greater than 300 kHz do not require tracking adjustment. Use SRCTK to<br />

improve amplitude accuracy <strong>and</strong> maximize signal response. Use SRCTKPK to adjust tracking<br />

automatically. See “SRCTKPK. n<br />