OBW<br />

Occupied B<strong>and</strong>width<br />

OBW Occupied B<strong>and</strong>width<br />

Performs the occupied b<strong>and</strong>width measurement using the value for occupied b<strong>and</strong>width<br />

percent (OBWPCT). For example, if OBWPCT is set to 99 percent, OBW determines the 99<br />

percent power b<strong>and</strong>width.<br />

Syntax<br />

Equivalent Softkey: OCCUPIED BANDWDTH .<br />

Related Comm<strong>and</strong>s: ACPPAR, ACPSNGLM, ACPCONTM, ACPSP, OBWPCT.<br />

Example<br />

OUTPUT 718*"OBW*"<br />

9 ><br />

Description<br />

OBW<br />

OBW measures the power b<strong>and</strong>width of the measured spectrum based on the value of occupied<br />

b<strong>and</strong>width percent (OBWPCT). OBW also measures transmit frequency error (the difference<br />

between the center frequency <strong>and</strong> the midpoint of the percent occupied b<strong>and</strong>width), <strong>and</strong> the<br />

total power of the occupied b<strong>and</strong>width. OBW performs the measurement using the value for<br />

channel spacing (ACPSP).<br />

To use OBW:<br />

1. Set the center frequency to the carrier’s frequency.<br />

2. For best accuracy, set the reference level so that the carrier signal peak is within the first<br />

(top) division of the screen graticule.<br />

3. Select the channel spacing with the ACPSP comm<strong>and</strong>.<br />

4. If you want the spectrum analyzer settings to be set automatically, ensure that ACPPAR is<br />

set to 1. If you want to set the spectrum analyzer settings manually, set ACPPAR to 0. See<br />

“ACPPAR” for more information about selecting the spectrum analyzer settings manually.<br />

5. If the spectrum analyzer is in the continuous-sweep mode, use the single sweep comm<strong>and</strong><br />

(SNGLS) to select the single-sweep mode.<br />

6. Execute the OBW comm<strong>and</strong>.<br />

7. Query OBWBW, OBWLOWER, OBWUPPER, OBWFERR, <strong>and</strong> OBWPWR variables for the<br />

numeric results of the OBW measurement. See the following table for more information<br />

about these variables.<br />

8. Query trace A (TRA) for the trace results of the OBW measurement.<br />

Measurement Results: The results of the OBW comm<strong>and</strong> are stored in the variables <strong>and</strong> trace<br />

in the following table.<br />

Programming Comm<strong>and</strong>s 5-387