LIMISEGT Enter Limit-Line Segment for Sweep Time<br />

� POINT specifies a limit value for the coordinate point, <strong>and</strong> no other sweep time points, so<br />

that a POINT segment specifies an amplitude value for a single sweep time. For an upper<br />

limit line, a POINT segment is indicated by a line drawn from the coordinate point, to a point<br />

that is vertically off the top of the graticule area. For a lower limit line, a POINT segment<br />

is indicated by a line drawn from the coordinate point, to a point that is vertically off the<br />

the limit-line table. However, if the last segment in the table is not specified as the POINT<br />

edge of the display is not desired, add an explicit last point segment to (higher in sweep time<br />

Segments are sorted according to starting sweep time. A maximum of 20 segments can be<br />

Use LIMISEGT if you want to enter amplitude data in the upper or lower limit lines. Use<br />

LIMIMODE to specify entry into the upper limit-line table or the lower limit-line table (see line<br />

30 of example). If you want to enter amplitude data as upper <strong>and</strong> lower amplitude pairs or as<br />

mid <strong>and</strong> delta pairs, use the SENTERT comm<strong>and</strong> instead of LIMISEGT.<br />

5-280 Programming Comm<strong>and</strong>s