09.12.2012 Views

HP 8590 E & L Series Spectrum Analyzers and HP 8591C Cable TV ...

HP 8590 E & L Series Spectrum Analyzers and HP 8591C Cable TV ...

HP 8590 E & L Series Spectrum Analyzers and HP 8591C Cable TV ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

FFTAUTO<br />

Marker to Auto FFT<br />

Performs a fast Fourier transform (FIT) on the signal on which the marker is placed.<br />

Syntax<br />

Equivalent Softkey: MARKER -> AUTO FFT .<br />

Prerequisite Comm<strong>and</strong>s: Use a marker comm<strong>and</strong> to place a marker on the signal of interest.<br />

See YIhble 5-4 for a list of the marker comm<strong>and</strong>s.<br />

Related Comm<strong>and</strong>s: FFI’CONTS, FFTOFF, FFTSNGLS.<br />

Example<br />

This example can be used to perform an FF”I’ continuously on an amplitude modulated signal at<br />

100 MHz.<br />

OUTPUT 718*"RL ODB-" Sets reference level to 0 dBm.<br />

OUTPUT 718&F 100ilHZ;" Sets the center frequency to 100 MHz.<br />

OUTPUT 718."SP , IOMHZ-" t Decreases the freqwncg span.<br />

OUTPUT 718."MKPK , HI-" , Places the marker on a signal (this example oxwnes that there<br />

is only one signal present).<br />

OUTPUT 718;"FFTAUTO;" Zoom in on the sip&, <strong>and</strong> then does an FFT continuously<br />

on the modulated siml.<br />

Description<br />

FFTAUTO uses the marker’s position to determine which signal is to be measured. FFIAUTO<br />

centers the signal <strong>and</strong>, if the frequency span of the spectrum analyzer is greater than zero,<br />

decreases the frequency span to zero before performing an FFT on the signal. When the FFT is<br />

performed, the spectrum analyzer does the following:<br />

� Changes to the continuous sweep mode.<br />

� Changes to the linear amplitude scale.<br />

� If the current detector is the peak detector, changes to the sample detector.<br />

� If the initial frequency span was greater than 0 Hz, the spectrum analyzer adjusts the signal<br />

peak to within 0.5 division of the top graticule.<br />

� Does an FFT on trace A <strong>and</strong> then places trace A in both the clear-write <strong>and</strong> store-blank<br />

modes. (When the spectrum analyzer is in both the clear-write <strong>and</strong> store-blank modes, the<br />

trace data is still taken from the spectrum analyzer input during every measurement sweep,<br />

but the trace is not shown on the spectrum analyzer display.)<br />

� Places the results of the FFT in trace B, <strong>and</strong> then changes trace B to the view mode.<br />

FFTAUTO performs the FFT on the signal at the end of every sweep. After executing<br />

FFTAUTO, you should adjust the values for the resolution b<strong>and</strong>width, video b<strong>and</strong>width,<br />

<strong>and</strong> sweep time according to the highest modulation frequency of interest. The resolution<br />

b<strong>and</strong>width should be about ten times greater than the highest modulation frequency of<br />

interest, <strong>and</strong> the video b<strong>and</strong>width should be about 10 times higher than the highest modulation<br />

frequency of interest. The sweep time should be set according to the chart shown in<br />

5-l 64 Programming Comm<strong>and</strong>s

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!