PR<br />

Plot Relative<br />

Moves the pen to a new plot location on the spectrum analyzer screen relative to the current<br />

coordinates in display units.<br />

Syntax<br />

x<br />

coordinate<br />

/ \<br />

Y.<br />

coordinate<br />

/ \<br />

number<br />

Item Description/Default Range<br />

Number Any valid integer. Dependent on the<br />

current pen position.<br />

Related Comm<strong>and</strong>s: DSPLY, PA, PLOT, PRINT, PU, TEXT.<br />

Example<br />

OUTPUT 718; “IP; ” Initializes spectrum aruzlym<br />

OUTPUT 7 18 ; “BLANK TRA ; ANNOT OFF ; ” Clears the display.<br />

OUTPUT 718;“GRAT OFF;” Turns off graticule.<br />

OUTPUT 718;“PU;PA 0,100;” Rxitions pen.<br />

OUTPUT 718;“PD;PR lOO,O,O,-lOO,-lOO,O,O,lOO;” Drawsa rectangle.<br />

Description<br />

Vector coordinate sets (x,y pairs) following the PR comm<strong>and</strong> can be either positive or negative,<br />

depending on the direction of the individual vectors to be drawn. PU (pen up) <strong>and</strong> PD (pen<br />

down) comm<strong>and</strong>s tell the spectrum analyzer to draw or not draw the vectors on the screen.<br />

(See “PU” <strong>and</strong> “PD.“)<br />

Display units are the scaling units of the spectrum analyzer display for on screen graphics<br />

comm<strong>and</strong>s such as PA or PR. See “PA” for more information about display units.<br />

The coordinates of the lower left screen corner of the screen are -4O,-22 <strong>and</strong> the upper right<br />

screen corner of the screen are 471,233. For the graticule area, the coordinates of the lower<br />

left corner of the graticule are 0,O <strong>and</strong> the coordinates of the upper right graticule area are<br />

400,200. For example, you could execute “PU;PA 0,O;PD;PA 0,200,400,200,400,0,0,0;” to draw<br />

a box around the graticule area.<br />

Because PR is an active function, executing PR causes the active function area on the spectrum<br />

analyzer screen to blank. To prevent the text following PR from being written in the active<br />

function area, execute hold (HD) after PR.<br />

5444 Programming Comm<strong>and</strong>s<br />