ENTER Enter From <strong>HP</strong>-IB<br />

Note Disconnect the computer before pressing softkey 1 or execute ABORT 7,<br />

LOCAL 7 from the computer. To execute the P-OP function, the spectrum<br />

analyzer must be the only controller on the <strong>HP</strong>-IB.<br />

10 OUTPUT 718;"VARDEF P-ONEX,l,VARDEF P-ONEY,l;"<br />

20 OUTPUT 718;"VARDEF PmTWOX,l;VARDEF PmTWOY,l;"<br />

30 OUTPUT 718;"FUNCDEF P-OP,Q";<br />

40 OUTPUT 718;"OUTPUT 5,B,79;";<br />

50 OUTPUT 718;"OUTPUT 5,B,80;";<br />

60 OUTPUT 718;"OUTPUT 5,B,59;";<br />

70 OUTPUT 718;"ENTER 5,K,P,ONEX;";<br />

80 OUTPUT 718;"ENTER 5,K,P,ONEY;";<br />

90 OUTPUT 718;"ENTER S,K,P-TWOX;";<br />

100 OUTPUT 718;"ENTER 5,K,P_TWOY;";<br />

110 OUTPUT 718;"PU;PA 200,190;DSPLY P-ONEX,l0.2;";<br />

120 OUTPUT 718;"PU;PA 200,180;DSPLY P-ONEY,l0.2;";<br />

130 OUTPUT 718;"PU;PA 200,170;DSPLY P,TWOX,l0.2;";<br />

140 OUTPUT 718;"PU;PA 200,160;DSPLY P,TWOY,l0.2;";<br />

150 OUTPUT 718;"REL<strong>HP</strong>IB;";<br />

160 OUTPUT 718;"@;"<br />

170 OUTPUT 718;"KEYDEF l,P,OP,!DSP OP;!;"<br />

180 END<br />

Description<br />

Declares the variables used to<br />

hold the plotter coordinates.<br />

Declares the variables used to<br />

hold the plotter- coordinates.<br />

D&nes a function called P-OI?<br />

Sends ASCII co& for “0”.<br />

Sends ASCII code for “P”.<br />

Seno!s ASCII code for “; “.<br />

Gets plotter coordinates from<br />

plotter:<br />

Gets Y coordinutefrom plot&x<br />

Gets Xcoordinutefrom plotter:<br />

Gets Y coordinate from plotter<br />

Displays coordinate on spectrum<br />

analyzer screen.<br />

Displays coordinate on spectrum<br />

analyzer screen.<br />

Displays coordinate on spectrum<br />

anulyz47.r screen.<br />

Displays coordinate on spectrum<br />

analyzer screen.<br />

Releases spectrum analyzer control<br />

of the <strong>HP</strong>-IR<br />

Marks the end of the function,<br />

P-OR<br />

Assigns the P-OP function to<br />

sojtkey 1.<br />

Use the ENTER comm<strong>and</strong> to request data from an <strong>HP</strong>-IB device. The ENTER comm<strong>and</strong> causes<br />

the spectrum analyzer to assume controller capabilities on <strong>HP</strong>-IB. The REL<strong>HP</strong>IB comm<strong>and</strong> may<br />

be used to disable these capabilities. The returned data is formatted according to the format<br />

specified in the format field:<br />

K: Free field. ASCII real number format.<br />

B: One-byte binary.<br />

W: One-word (2 bytes) binary.<br />

6-150 Programming Comm<strong>and</strong>s