TO1<br />

Third-Order Intermodulation Measurement<br />

Turns on or off the third-order inter-modulation (TOI) measurement.<br />

Syntax<br />

Equivalent Softkey: TO1 ClN OFF .<br />

Related Comm<strong>and</strong>s: AUNITS, MKPX, TH, TOIR.<br />

Example<br />

OUTPUT 718*"MOV TO1 1."<br />

, , ,<br />

OUTPUT 718*"TOIR'."<br />

f - ,<br />

ENTER 718;Toi<br />

PRINT 'Third-order intermodulation is ",Toi<br />

OUTPUT 718;"MOV TOI,O;"<br />

Description<br />

Tums on the third-order intemnodul&ion<br />

measurement.<br />

Queries TOIR. TOIR contains the results<br />

of the third-order intermdulation<br />

measurement.<br />

Stores the value of TOIR in the variable<br />

lbi.<br />

Prints the results.<br />

Turns off the third-order interrnodul&ion<br />

measurement.<br />

Setting TO1 to 1 turns on the third-order intermodulation measurement. Setting TO1 to 0 turns<br />

off the third-order intermodulation measurement. When the third-order intermodulation<br />

measurement is turned on, the spectrum analyzer first determines that there are four signals<br />

on the spectrum analyzer display; the four signals must be the two fundamental signals <strong>and</strong><br />

two distortion products. All of the signals must be greater than the peak excursion above<br />

the threshold. If four valid signals could not be found for the third-order intermodulation<br />

measurement, the value of TOIR is -100. If four valid signals could be found, the spectrum<br />

analyzer does the following:<br />

1. Finds the four highest on-screen signals. (If the four highest on-screen signals are not the<br />

two signals <strong>and</strong> two distortion products, the TO1 measurement cannot be performed.)<br />

2. Determines the spacing between the highest two signals. The highest two signals are tone A<br />

<strong>and</strong> tone B.<br />

3. Verifies that the third <strong>and</strong> fourth highest signals (distortion A <strong>and</strong> distortion B) fall above<br />

<strong>and</strong> below tone A <strong>and</strong> tone B by the frequency difference between tone A <strong>and</strong> tone B.<br />