Example<br />

10 CLEAR 718<br />

20 OUTPUT 718.“IP-”<br />

30 OUTPUT 7181”FA’lOOMHZ;FB 1100MHZ;”<br />

40 OUTPUT 718;“TS;MKPK HI;”<br />

50 OUTPUT 718; “DL ON; ”<br />

60 OUTPUT 718;“MOV DL,MKA;”<br />

70 END<br />

Description<br />

MOV Move<br />

Clears the <strong>HP</strong>-IB bus <strong>and</strong> spectrum analyzxx<br />

Initializes spectrum analyzer<br />

Sets up the measurement range.<br />

Places a marker at the highest peak.<br />

Turns on display line.<br />

Sets the display-line value equal to the marker<br />

amplitude by storing the value of the marker<br />

amplitude variable, MKA, in the display line<br />

variable, DL.<br />

When the source is longer than the destination, the source is truncated to fit. When the source<br />

is shorter than the destination, the last element is repeated to fill the destination.<br />

Programming Comm<strong>and</strong>s 5.371