10 CLEAR 718<br />

20 OUTPUT 718;"IP;SNGLS;CF 300MHZ;SP 20MHZ;TS;"<br />

30 OUTPUT 718;"MKPK HI;MKRL;TS;MKF?;"<br />

40 ENTER 718 USING "K";Mk,freq<br />

50 OUTPUT 718;"MKA?;"<br />

60 ENTER 718 USING "K";Mk-amp<br />

70 OUTPUT 718;"SS ";Mk-freq;"HZ"<br />

80 OUTPUT 718;"CF UP;TS;MKPK HI;MKA?;"<br />

90 ENTER 718;Mk-amp1<br />

100 PRINT "THE FUNDAMENTAL IS ";Mk-amp-Mk,amp1<br />

110 PRINT "dB ABOVE THE SECOND HARMONIC"<br />

120 END<br />

Description<br />

SS Center Frequency Step Size<br />

Clears the <strong>HP</strong>-B<br />

Initializes the spectrum an&yactivatessingle-sweep<br />

mode, changes<br />

the center frequency, span, takes<br />

sweep.<br />

Finds the highest peak, changes<br />

the reference level to the markq<br />

takes sweep, returns the frequency<br />

of the marker:<br />

Puts the spectrum analyzer response<br />

in the computer variable,<br />

h!k-freq.<br />

Returns the amplitude of the marker<br />

Puts the spectrum analyzer response<br />

in the computer variable,<br />

h<strong>&amp</strong>.<br />

Changes the step size to the marker<br />

freq-u<br />

Increases the centerfrequency, takes<br />

sweep, puts the marker on the<br />

highest peak <strong>and</strong> returns the amplitude<br />

of the marker<br />

Puts the spectrum analyzer response<br />

in the computer variable,<br />

Mk-ampl.<br />

Outputs the result.<br />

The AUTO parameter removes SS as an active function but does not have an effect on its value.<br />

Query Response<br />

Programming Comm<strong>and</strong>s 5.525