09.12.2012 Views

HP 8590 E & L Series Spectrum Analyzers and HP 8591C Cable TV ...

HP 8590 E & L Series Spectrum Analyzers and HP 8591C Cable TV ...

HP 8590 E & L Series Spectrum Analyzers and HP 8591C Cable TV ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IP Instrument Preset<br />

MS1<br />

NDB<br />

PD<br />

PKDLMODE<br />

PKSORT<br />

PKTBL<br />

PKZOOM<br />

QPOFFSET<br />

RB<br />

RL<br />

RLPOS<br />

ROFFSET<br />

RQS 40<br />

SPEAKER<br />

SQLCH<br />

SRCALC<br />

SRCNORM<br />

SRCPSWP<br />

SRCPWR<br />

ss<br />

STATUS BYTE<br />

TH<br />

TITLE<br />

TM<br />

TDF<br />

TRB<br />

TRC<br />

<strong>TV</strong>LINE<br />

<strong>TV</strong>SYNC<br />

VAVG<br />

VB<br />

VBR<br />

5-244 Programming Comm<strong>and</strong>s<br />

Selects the spectrum analyzer memory as the mass storage device.<br />

Sets the number of dB for the NDBPNT measurement to -3 dB.<br />

Puts pen down at current position.<br />

Displays all the signal peaks in the peak table.<br />

Sorts the signal peaks in the peak table by decreasing amplitude.<br />

Turns off the peak table.<br />

Sets the final span for the peak zoom routine to 1 MHz.<br />

Sets the QPOFFSET to 20. (Option 103 only.)<br />

Sets the resolution b<strong>and</strong>width to 3 MHz.<br />

Sets reference level to 0 dBm.<br />

Sets the reference level position to 8.<br />

Sets reference offset to 0.<br />

Allows SRQ 110, SRQ 140 for illegal comm<strong>and</strong>s or broken hardware.<br />

Turns on the speaker. (Option 102, 103, or 301 only.)<br />

Sets the squelch level to 0. (Option 102 or 103 only.)<br />

Sets the source leveling control to internal. (Option 010 or 011 only.)<br />

Sets the source normalization to off. (Option 010 or 011 only.)<br />

Sets the source power sweep to off. (Option 010 or 011 only.)<br />

Sets the source power level to -10 dBm. (Option 010 or 011 only.)<br />

Sets the center frequency step size to 100 MHz.<br />

Clear the status byte.<br />

One division above bottom graticule line, threshold line off.<br />

Clears the title from the spectrum analyzer screen.<br />

Selects free run trigger mode.<br />

Selects parameter units output format.<br />

Sets the trace values to 0.<br />

Sets the trace values to 8000.<br />

Sets <strong>TV</strong> line number to 17. (Options 101 <strong>and</strong> 102, or 301 only.)<br />

Triggers on negative polarity of the video modulation. (Options 101<br />

<strong>and</strong> 102, or 301 only.)<br />

Turns off video averaging <strong>and</strong> sets the video averaging limit to 100.<br />

Sets the video b<strong>and</strong>width to 1 MHz.<br />

Sets VBR to 0.300.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!