KEYDEF User-Defined Key Definition<br />

Item<br />

User-de&ted variable<br />

Predefined function<br />

Trace element<br />

Number<br />

Predefined variable<br />

Delimiter<br />

Analyzer comm<strong>and</strong><br />

User-defined function<br />

Character<br />

Description/Default Range<br />

A variable deEned by VARDEF or ACTDEF comm<strong>and</strong>s. Any valid variable<br />

name.<br />

Function that returns a value. Refer to lhble 5-l. Any valid predeflned<br />

function that returns<br />

a value within the<br />

softkey number range.<br />

An element of trace A, trace B, trace C, or a user-defined trace.<br />

Any valid integer. 1 to 6, 601 to 1200.<br />

A comm<strong>and</strong> that acts as a variable. Refer to Table 5-l. Any valid predeflned<br />

variable that returns a<br />

value within softkey<br />

number range.<br />

Matching characters marking the beginning <strong>and</strong> end of the list of - 1 \ @ = / ^ $ % ; ! ’ :<br />

spectrum analyzer comm<strong>and</strong>s. ” &<br />

Any valid spectrum analyzer comm<strong>and</strong>.<br />

A subroutine de&red by the FUNCDEF comm<strong>and</strong>. Any valid function<br />

name.<br />

Any valid character. Bee “LB” for additional characters <strong>and</strong> label 1 to 8 characters per<br />

functions. label line, use the (I)<br />

symbol or blank<br />

spaces to separate<br />

softkey label lines.<br />

Prerequisite Comm<strong>and</strong>s: ACTDEF or VARDEF when using a user-defined variable.<br />

Related Comm<strong>and</strong>s: DISPOSE, ERASE, FUNCDEF, KEYEXC, KEYLBL.<br />

Example 1<br />

Connect CAL OUT to the spectrum analyzer input.<br />

OUTPUT 718*"IP*"<br />

OUTPUT 718;"FUkDEF D-LP,Q";<br />

OUTPUT 718;"CF 300MHZ;";<br />

OUTPUT 718;"SP IMHZ;";<br />

OUTPUT 718."(9."<br />

3 ,<br />

OUTPUT 718;"KEYDEF l,D,LP,%SHOWICAL%;"<br />

OUTPUT 718;"KEYEXC 1;"<br />

5-252 Programming Comm<strong>and</strong>s<br />

Initializes spectrum analyzex<br />

L%@u?s a function called D-L?<br />

Changes center frequency to measure the<br />

calibration signal.<br />

Measures the calibration signal in narrow<br />

span.<br />

The ‘@” signifies the end of the &n&ion<br />

declaration.<br />

SojZkey 1 will now have the “‘SHOW CAL”<br />

label <strong>and</strong> perform thejbnction D-LI?<br />

Exectutes sofikey 1.