LINFILL Line Fill<br />

Item<br />

User-defined variable<br />

Predefined variable<br />

Predefined function<br />

Trace element<br />

Number<br />

Example<br />

Description/Default R-f&<br />

A variable deEned by VARDEF or ACTDEF Any valid variable name.<br />

comm<strong>and</strong>s.<br />

A comm<strong>and</strong> that acts as a variable. Refer to<br />

‘lhble 5-1.<br />

Function that returns a value. Refer to ‘lhble<br />

5-l.<br />

An element of trace A, trace B, trace C, or a<br />

user-defined trace.<br />

Any valid integer number. For the starting value or number of<br />

elements, the range of the number is 0 to<br />

the length of the trace minus 1. For the<br />

ending value, the range is -32,763 to<br />

+ 32,767.<br />

OUTPUT 718;"LINFILL TRC,O,O,O;" Initializes trace C.<br />

OUTPUT 718;"MOV TRC[l,lO] ,TRA[l,lOl;" Moves the jirst 10 elements of trace A into<br />

trace C.<br />

OUTPUT 718;"LINFILL TRC,l0,40,8000;" Uses the 10th element of trace C as the starting<br />

valwq fills trace C elements 11 through 50<br />

with the interpolated data, <strong>and</strong> places ending<br />

value (8000) into the 50th element of trace<br />

C.<br />

Description<br />

LINFILL uses the value of the starting value <strong>and</strong> the ending value to calculate the linear<br />

interpolation data (the values for ending value should be in measurement units). The “number<br />

of elements” field allows you to specify the number trace data points that are “filled in” with<br />

linear interpolation data. The number of elements field includes the starting element, so if the<br />

starting value is 10 <strong>and</strong> the number of elements is 40, the ending element will be 50.<br />

The data will not be interpolated if the starting value is 0. If the starting value is 0, the ending<br />

value is copied into the first element of the destination trace. You may want to set the starting<br />

value to 0 to initialize a trace before using LINFILL to fill the trace with interpolated data. If<br />

the starting value <strong>and</strong> the number of elements exceed the length of the destination trace, the<br />

interpolation ends at the end of the trace array; the ending value is never reached.<br />

5.284 Programming Comm<strong>and</strong>s