MKMIN<br />

Marker Minimum<br />

Moves the active marker to the minimum value detected.<br />

Syntax<br />

Related Comm<strong>and</strong>s: MKPK, SMOOTH, TH, VAVG.<br />

Example<br />

10 OUTPUT 718;"IP;SNGLS;"<br />

20 INPUT "ENTER IN THE START FREqUENCY,<br />

IN MHZ",Start,freq<br />

30 INPUT "ENTER IN THE STOP FREQUENCY,<br />

IN MHZ",Stop,freq<br />

40 OUTPUT 718;"FA ";Start-freq;"MHZ"<br />

50 OUTPUT 718;"FB ";Stop,freq;"MHZ"<br />

60 OUTPUT 718;"TS;MKPK HI;MKD;MKMIN;MKF?;"<br />

70 ENTER 718;Delta-freq<br />

80 PRINT "DIFFERENCE IN FREqUENCY IS ",<br />

Delta-freq,"HZ"<br />

90 END<br />

MKMIN Marker Minimum<br />

Initializes spectrum analym activates<br />

single-sweep mode.<br />

Sets the start frequency.<br />

Sets the stop frequency.<br />

Updates trace, jinds trace peak, turns on<br />

marker delta function, jinds the minimum<br />

value of trace, <strong>and</strong> return the frequency<br />

delta.<br />

Gets the result from spectrum analyzer<br />

Programming Comm<strong>and</strong>s 5-341