MKA<br />

Marker Amplitude<br />

MKA Marker Amplitude<br />

Specifies the amplitude of the active marker in the current amplitude units when marker type<br />

is of fixed or amplitude type. When queried, MKA returns the marker amplitude independent<br />

of marker type.<br />

Syntax<br />

MKA<br />

ompl i tude<br />

Item Description/Default R-fxe<br />

Number Any real or integer number. Unit is current amplitude type. Amplitude range of<br />

spectrum analyzer.<br />

Step Increment: by 1 dB.<br />

Related Comm<strong>and</strong>s: AUNITS, AUTO, MA, MKD, MKN, MKTYPE, TDF.<br />

Example<br />

OUTPUT 718*"IP*"<br />

Initializes the spectrum analyzex<br />

OUTPUT 718;"MK;YPE AMP;" Changes the marker type to amplitude.<br />

OUTPUT 718;"MKA -50;" Places the marker at -50 dBm.<br />

Description<br />

The MKA comm<strong>and</strong> specifies the amplitude of the active marker in current units when the<br />

marker is the fixed or amplitude type (see “MKTYPE”). If both the delta marker <strong>and</strong> active<br />

marker are on the screen, “MKA?;” returns the amplitude difference between the two markers.<br />

Specifying the marker amplitude moves the marker to the point of the trace closest to the<br />

given marker amplitude.<br />

If the trace data format P (TDF P), is used with MKA, the result is one real value in the current<br />

amplitude units (AUNITS can be used to change the current amplitude units).<br />

XMKA<br />

Programming Comm<strong>and</strong>s 5-325