FFTSNGLS<br />

FFT Single Sweep<br />

Changes the spectrum analyzer’s sweep mode to single sweep mode (if necessary), <strong>and</strong> then<br />

performs a fast Fourier transform (FFT) on trace A.<br />

Syntax<br />

Equivalent Softkey: SINGLE FFT .<br />

Prerequisite Comm<strong>and</strong>s: LN, Sl?<br />

Related Comm<strong>and</strong>s: FFI’CONTS, FFTOFF<br />

Example<br />

OUTPUT 7 18 . “SP OHZ # * ”<br />

OUTPUT 7 18 ; “LN ; ”<br />

Sets the spectrum analyzer to zero span.<br />

Changes the amplitude scale to linear:<br />

OUTPUT 718 ; “FFTSNGLS ; ” Ftyforms the FFi?<br />

Description<br />

You should change the frequency span to 0 Hz <strong>and</strong> the amplitude scale to linear before<br />

executing FFTSNGLS. How FFTSNGLS performs the FFT depends on the current sweep mode,<br />

the trace status of trace A, <strong>and</strong> if FFTSNGLS is already active.<br />

� If the spectrum analyzer is in the single-sweep mode or trace A is in the view mode when<br />

FFISNGLS is first executed, the spectrum analyzer does an FFT on trace A without updating<br />

the contents of trace A.<br />

� If the spectrum analyzer is in the continuous-sweep mode when FFTSNGLS is executed, the<br />

spectrum analyzer changes to the single sweep mode, <strong>and</strong> then does an FFT on trace A.<br />

� If the spectrum analyzer is currently performing the FFTSNGLS comm<strong>and</strong>, a take sweep is<br />

performed <strong>and</strong> then an FFI’ is performed on trace A.<br />

FFTSNGLS does the following when performing an FFT:<br />

� If the current detector is the peak detector, the detector is changed to the sample detector.<br />

� Places trace A in both the clear-write <strong>and</strong> store-blank modes. (When the spectrum analyzer is<br />

in both the clear-write <strong>and</strong> store-blank modes, the trace data is still taken from the spectrum<br />

analyzer input during every measurement sweep, but the trace is not shown on the spectrum<br />

analyzer display.)<br />

� Places the results of the FFT in trace B, <strong>and</strong> then changes trace B to the view mode.<br />

Restrictions<br />

Executing FFTSNGLS exits the following functions: windows display mode (WINON), N dB<br />

point measurement (NDBPNT), gate utility functions (GDRVUTIL), TO1 measurement (TOI),<br />

marker table (MKTBL), peak table (PKTBL), percent AM (PCTAM), peak zoom (PKZOOM),<br />

power menu measurements (ACP, ACPE, C<strong>HP</strong>, <strong>and</strong> OBW), <strong>and</strong> Analog+ display mode<br />

(ANLGPLUS).<br />

You can use the results of the FFTCLIP comm<strong>and</strong> to determine if the FFT data is valid.<br />