P 16<br />

Title<br />

VALIDITy OF ALVEOLAR bONE MEASuREMENTS uSING SINGLE AND STITCHED CbCT<br />

VOLuMES<br />

Authors<br />

E. SOGuR 1 , E. ONEM 1 , b.G. bAKSI 1<br />

Affiliations<br />

1 Ege University, School of Dentistry, Department of Oral & Maxillofacial Radiology, Izmir,<br />

TURKEY<br />

Body<br />

Objective: To validate the accuracy of bone height and width me<strong>as</strong>urements obtained with<br />

single and stitched volumes of a cone beam computed tomography (cbct) system by comparing<br />

them to direct digital caliper me<strong>as</strong>urements.<br />

Methods: Fiducial markers were placed on both lingual and buccal cortical plates of ten dry<br />

mandibles to define different planes. Two different widths and two different heights on anterior<br />

and posterior regions were me<strong>as</strong>ured on Kodak 9000 3D cbct images. Each mandible w<strong>as</strong><br />

scanned 4 times - three for right, anterior, left single volumes and the fourth for the stitched<br />

volume. Total of 480 me<strong>as</strong>urements were made on forty volumes by 3 observers. Gold standard<br />

w<strong>as</strong> determined using caliper me<strong>as</strong>urements. Comparison with the gold standard w<strong>as</strong> done with<br />

Bland and Altman plots. Experimental groups were compared using Dunnett test. Correlation<br />

of me<strong>as</strong>urements w<strong>as</strong> <strong>as</strong>sessed with Pearson’s correlation analysis.<br />

Results: No differences were found in the height and width me<strong>as</strong>urements between single and<br />

stitched volumes for both anterior (pheight=0.95, pwidth=0.63) and posterior (pheight=0.86,<br />

pwidth=0.67) me<strong>as</strong>urements. The mean difference in width me<strong>as</strong>urements w<strong>as</strong> 0.99 mm for<br />

single while it w<strong>as</strong> 1.04 mm for stitched volumes. Mean difference in height me<strong>as</strong>urements<br />

were 0.97 mm and 1.07 mm for single and stitched volumes respectively. The correlation between<br />

observers w<strong>as</strong> 0.972 and 0.964 for posterior; 0.991 and 0.977 for anterior me<strong>as</strong>urements<br />

of single and stitched volumes respectively.<br />

Conclusions: Me<strong>as</strong>urements obtained on the stitched volumes of Kodak 9000 3D show a high<br />

level of agreement with single volume me<strong>as</strong>urements and actual anatomical distances.<br />

Keywords<br />

cone beam CT,dimensional accuracy,stitching<br />

POSTerS<br />

131