18.02.2013 Views

Program including abstracts as pdf available here

Program including abstracts as pdf available here

Program including abstracts as pdf available here

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

OP 65<br />

Title<br />

ASSESSING bONE THICKNESS AND AuGMENTATION MATERIAL uSING CbCT<br />

Authors<br />

A. KÜNzEL 1 , D. WANG 2 , V. GOLubOVIC 1 , I. MIHATOVIC 1 , J. bECKER 1 , F. SCHWARz 1<br />

Affiliations<br />

1 Department of Oral Surgery, Heinrich-Heine-University, Düsseldorf, GERMANY, 2 Department<br />

of Oral Implantology, Guanghua School, Sun Yat-sen University, Guangzhou, CHINA<br />

Body<br />

Objectives: Evaluation of the accuracy me<strong>as</strong>uring bone thickness and of existence and completed<br />

integration of augmentation material at dental implants.<br />

Methods: In an animal experiment dog jaws with artificial defects treated with GTR-techniques<br />

were exposed in CBCT (PaX Duo3D®, FoV 50x50 mm, Voxelsize 80 µm, 85 kV, 4,9 mA) and<br />

investigated histologically. Bone thickness w<strong>as</strong> me<strong>as</strong>ured and the existence and completion of<br />

osseous integration w<strong>as</strong> evaluated both in CBCT and in histological images.<br />

Results (preliminary): The mean and the standard deviation of the differences between radiological<br />

and histological me<strong>as</strong>urements of peri-implant bone thickness were -0.22 mm and 0.78<br />

mm respectively and without significance. Sensitivity and specificity were 0.77 and 0.60 for<br />

the existence of BAM, 0.59 and 0.74 completion of osseous integration and 0.39 and 0.71 for<br />

the completeness of bone covering of the implant surface.<br />

Conclusion: The accuracy of peri-implant me<strong>as</strong>urements seems limited by a high standard deviation.<br />

To some extent it might be possible to evaluate the existence and integration of bone<br />

augmentation material but not the completeness of bone covering the implant surface.<br />

Keywords<br />

Radiography, Dental, Digital, Cone-Beam Computed Tomography, Implants, Dental<br />

70

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!