Accessories 101<br />

Fire Point<br />

The lowest temperature at which the vapor will continue to burn<br />

when a flame is applied.<br />

Flash Point<br />

The temperature at which the vapor from an oil will flash when<br />

a flame is applied under st<strong>and</strong>ard conditions. The flash point minimums<br />

are set to meet safety limits for products lighter than lube oil.<br />

Flash point is useful in detecting contamination of the lube oil by fuel<br />

oils. Typical values for flash point are listed in Table 6-1:<br />

Table 6-1.<br />

————————————————————————————————<br />

Product<br />

Flash Point<br />

————————————————————————————————<br />

<strong>Gas</strong>oline<br />

>32°F (0°C)<br />

————————————————————————————————<br />

Diesel Fuel<br />

150°F (65°C) to 200°F (93°C)<br />

————————————————————————————————<br />

Lube Oil<br />

300°F (149°C) to 650°F (343°C)<br />

————————————————————————————————<br />

Pour Point<br />

The lowest temperature at which an oil will flow when cooled<br />

under st<strong>and</strong>ard conditions.<br />

Cloud Point<br />

The temperature at which a cloud of wax crystals appear when<br />

oil is cooled under certain st<strong>and</strong>ard conditions.<br />

Flock Point<br />

The temperature at which wax separates as a flock when a mixture<br />

of 10% oil <strong>and</strong> 90% refrigerant is cooled under certain conditions.<br />

These temperatures define the flow properties of oil under low<br />

temperature conditions (pour <strong>and</strong> cloud points are for non-miscible<br />

refrigerants <strong>and</strong> flock point is for miscible refrigerants). This property<br />

is significant to refrigeration <strong>and</strong> air conditioning plant compressor<br />

operators. Pour points of –30°F (–34°C) to –40°F (–40°C) or flock<br />

points of –60°F (51°C) to –70°F (–57°C) are necessary.