Case Study #1 237<br />

Table 14-1. Expected Plant Performance on SYNGAS*<br />

————————————————————————————————<br />

Heat Input (10 6 Btu/Hr) LHV/HHV[KJ/Hr] 807.3[850.9]/836.6[881.9]<br />

————————————————————————————————<br />

Combustion <strong>Turbine</strong> Power (MW) 61<br />

————————————————————————————————<br />

Steam <strong>Turbine</strong> Power (MW) 46<br />

————————————————————————————————<br />

Steam <strong>Turbine</strong> Conditions (psia[Bars]/°F[°C]) 950[65.50]/950[510]<br />

————————————————————————————————<br />

Station Load (MW) 7<br />

————————————————————————————————<br />

Net Power Output (MW) 100<br />

————————————————————————————————<br />

Heat Rate(Btu/kWhr) LHV/HHV[KJ/kWhr] 8096[8534]/8390[8844]<br />

————————————————————————————————<br />

*At 50°F[10°C] <strong>and</strong> 4280'[1305m] elevation, evaporative cooler off.<br />

Table 14-2. Expected Plant Performance vs. Temperature.<br />

——————————————————————————————————<br />

Ambient Temperature 5°F*[–15°C] 50°F[10°C] 95°F**[35°C]<br />

——————————————————————————————————<br />

Expected Performance - Coal<br />

——————————————————————————————————<br />

Net Power Output (MW) 102 100 96<br />

——————————————————————————————————<br />

Heat Rate (Btu/kWhr) LHV/HHV 7956/8245 8096/8390 8154/8450<br />

——————————————————————————————————<br />

(KJ/kWhr) LHV/HHV 8387/8691 8534/8844 8596/8908<br />

——————————————————————————————————<br />

Expected Performance - Natural <strong>Gas</strong><br />

——————————————————————————————————<br />

Net Power Output (MW) 91 88 84<br />

——————————————————————————————————<br />

Heat Rate (Btu/kWhr) HHV 8103 8144 8207<br />

——————————————————————————————————<br />

(KJ/kWhr) HHV 8541 8584 8717<br />

——————————————————————————————————<br />

*5°F[–15°C] Data do not include spiking.<br />

**95°F[35°C] Data include evaporative cooling.)