<strong>Gas</strong> <strong>Turbine</strong> Inlet Treatment 117<br />

water to wet the evaporative cooler pads. In this case, the DI water<br />

would break down the bond in the evaporative cooler pads <strong>and</strong> the<br />

filter (assuming that the filters are downstream of the cooling flow)<br />

<strong>and</strong> reduce them to a mush-like substance. On the other h<strong>and</strong>, using<br />

water with a high calcium (C a<br />

) or calcium carbonate (C a<br />

CO 3<br />

) content<br />

would result in calcium deposits throughout the compressor <strong>and</strong> the<br />

cooling passages of the turbine.<br />

Also, contaminant particle size varies within each area. For<br />

example, in a desert environment 50% of the contaminant consists of<br />

particles smaller than 1.5 microns (μm). The following details the size<br />

of contaminant <strong>and</strong> the major components:<br />

>5.0 μm dust, rain, fog, chemicals, minerals <strong>and</strong> metals<br />

1-2 μm dust, salts, fog, soot, chemicals, minerals <strong>and</strong> metals<br />

0.3-0.5 μm hydrocarbon emissions, smog.<br />

INLET AIR FILTERS<br />

Filter types <strong>and</strong> configurations should be selected on the basis<br />

of the environment in which they are expected to operate, the<br />

amount of maintenance available, <strong>and</strong> the degree of protection expected.<br />

Inertial Separators are available with <strong>and</strong> without dust<br />

removal capability (Figure 8-1). They are useful in areas where<br />

there is a significant level of contaminants above 25 microns. Prefilters<br />

provide a similar function as the inertial separator <strong>and</strong> their<br />

initial cost is considerably lower. Intermediate Filters, with <strong>and</strong><br />

without viscous coating, help to extend the life of the high efficiency<br />

filter. Intermediate filters must be capable of capturing 30% or more<br />

of the target micron size of the problematic contamination in the<br />

environment. High Efficiency Filters must be capable of capturing<br />

in excess of 95% of the problematic contamination down to 1.0<br />

micron. Prefilters, intermediate filters, <strong>and</strong> high efficiency filters are<br />

commonly available in the barrier or pad type configuration. These<br />

are usually 24 inch × 24 inch square with depths ranging from 6<br />

inches to 24 inches (Figure 8-2). This configuration lends itself to<br />

stacked filters. That is the intermediate filter <strong>and</strong> the high efficiency<br />

filter elements may be mounted back to back. This is convenient <strong>and</strong><br />

economical.