responded in a fairly similar manner, confirming the effectiveness of the criteria developed for<br />

generating the structures. <strong>The</strong> maximum top displacement of the structures, within the same group,<br />

shows a slight increase as the concrete strength increases. This is consistent with the load-displacement<br />

curves generated under static loading. <strong>The</strong> higher strength concrete experiences slightly more<br />

softening beyond a certain strain, in the initial ascending branch of the curve. This is partially<br />

attributable to the cracking of the concrete cover. In all instances, the maximum top displacement of<br />

the structures in the R and RS groups are greater than those structures of the same concrete strengths in<br />

the E group.<br />

N80R N100R N120R<br />

FIGURE 4<br />

SAMPLE PLASTIC HINGE LOCATIONS<br />

(SHADED AREAS ARE PLASTIC HINGING IN THE WALL)<br />

<strong>The</strong> plastic hinges formed in the different structures show that the number of column hinges generally<br />

increases with increasing concrete strength. This is attributable to the higher strain levels in the steel,<br />

due to the increase in strength and modulus of elasticity of the concrete. Although the strong-column<br />

weak-beam provision of the code was satisfied in the design, the 120 MPa concrete structures in the R<br />

group show substantially more hinging in the columns, as shown in Figure 4. <strong>The</strong> use of high yield<br />

steel in the beams and normal grade steel in the columns of the R structures has an adverse effect in<br />

terms of increased number of column hinges. <strong>The</strong> RS group, which used high yield steel in the<br />

columns, had fewer column hinges, even at high levels of loading. On the other hand, the spread of<br />

inelasticity in the shear wall is unaffected by the change in concrete strength. <strong>The</strong> use of normal grade<br />

steel with high strength concrete does not cause undesirable consequences in the wall. For the beams,<br />

at twice the design PGA, yielding has occurred in almost all cases. This is both expected and desirable<br />

at this level of loading.<br />

To study local effects, the curvature ductility demand of a number of beams at different locations in<br />

the structure, was calculated. <strong>The</strong> maximum curvature ductility demand in the beams is shown in<br />

Table 6.