474<br />

quantities of interest are: (1) absolute acceleration which determines the forces acting on the shear<br />

walls; (2) the maximum relative displacement of the superstructure (in case of free sliding); and (3) the<br />

residual relative displacement which will indicate the position of the superstructure at the end of the<br />

ground motion. <strong>The</strong> following range of values of different parameters has been estimated, that would<br />

cover a wide variety of multistory masonry buildings:<br />

TABLE 3.1<br />

DATA FOR COMPUTING SEISMIC RESPONSE<br />

Time Period<br />

(TP) sec.<br />

0.40<br />

0.50<br />

0.60<br />

0.70<br />

0.80<br />

Mass Ratio<br />

(9)<br />

6 to 8<br />

8 to 10<br />

10 to 12<br />

12 to 14<br />

14 to 16<br />

Damping<br />

Coefficient<br />

(f)<br />

0.05 to 0.15<br />

0.05 to 0.15<br />

0.05 to 0.15<br />

0.05 to 0.15<br />

0.05 to 0.15<br />

Coefficient<br />

of friction<br />

(M.)<br />

0.10 to 0.25<br />

0.10 to 0.25<br />

0.10 to 0.25<br />

0.10 to 0.25<br />

0,10 to 0.25<br />

Restricted<br />

Sliding base<br />

range (A) mm<br />

2 to 130<br />

3 to 140<br />

2 to 150<br />

9 to 145<br />

2 to 165<br />

It is assumed that a coefficient of friction less than 0.10 in sliding will be difficult to obtain in actual<br />

building construction, and for a value greater than 0.25, no sliding motion may occur in most real<br />

earthquakes and the system may act just like a fixed-base structure. For four-story building, top three<br />

and half portion of the total mass of the building is assumed to be lumped as the top mass in the<br />

mathematical model. In the same way, as the story of the building increases, the mass ratio increases.<br />

In estimating the mass ratio, it is assumed that mass in each story is same.<br />

4. DISCUSSION OF RESULTS<br />

<strong>The</strong> influence of various parameters on maximum response of the free sliding (without stopper),<br />

restricted base sliding (with stopper) and fixed base multistory masonry buildings subjected to Koyna<br />

and El Centra shocks is presented in the present investigation through representative Figures 4.1 to 4.6.<br />

A comparison of the absolute acceleration response in the restricted base sliding has been made with<br />

that of the free sliding and fixed base buildings. <strong>The</strong> results of this study are discussed in the following<br />

paragraphs.<br />

Figs. 4.3 to 4.6 shows the typical acceleration response of the masonry buildings subjected to Koyna<br />

and El Centra earthquakes for different parameters. In these figures, the upper dashed line shows the<br />

maximum acceleration response in the fixed base structure, whereas the bottom dashed lines show the<br />

maximum acceleration developed in the building with free sliding base system during the seismic<br />

ground motion at different mass ratios. <strong>The</strong> firm lines show the maximum acceleration response<br />

computed in the buildings with the restricted base sliding system during the earthquakes at different<br />

mass ratios.<br />

4.1 Influence of Viscous Damping<br />

<strong>The</strong> representative acceleration response curves show that at a particular mass ratio, time period and<br />

coefficient of friction in the case of restricted base sliding buildings, an increase in viscous damping<br />

(from 5% to 15%) decreases the acceleration response (Figs. 4.1 and 4.2). This is perhaps because of<br />

increasing energy dissipation in the internal friction of the system as the damping coefficient increases.<br />

In view of this well-established trend, the acceleration response for other cases has not been studied.