541<br />

identification results of structural parameters while the averaged value x (t) obtained in stepS gives<br />

the time history of the ground motion.<br />

<strong>The</strong> key point of this improved method is the statistical average process in Steps 3 and 4, which<br />

actually provides a measure to convert the dynamics of structure under earthquake excitation into a<br />

mathematical condition that ensures the convergency of the iterative procedure. Moreover, the<br />

statistical average process is independent from the parameter identification algonthm chosen. In this<br />

connection, for special cases different parameter identification methods can be adopted instead of the<br />

least-squares method.<br />

NUMERICAL EXAMPLES<br />

<strong>The</strong> applicability of the dynamic compound inverse method is<br />

demonstrated in this section through a numerical example of a 3-<br />

story shear building (see Fig.3.1) under earthquake excitation (see<br />

Fig. 3.5) for both noise-free and noise contamination cases. <strong>The</strong><br />

properties of the building, as used by Yang and Agrawal (2000 j for<br />

a high tech building, are mi=350,25,m 2 =262.29 and m 3 =175.13/0rc;<br />

ci=4369, C2-291.3 and c 3 =145.6&Vs/m; ki=4728400, k 2 =315230<br />

and k3-157610AW/m. <strong>The</strong> three natural frequencies of the building<br />

"'<br />

are computed as 3.447, 7.372 and 19.155 Hz, with the<br />

corresponding modal damping ratios are 1%, 2.14% and 5.56%,<br />

respectively. <strong>The</strong> peak acceleration of the input ground motion is<br />

120cm/s 2 . <strong>The</strong> sampling time interval of the ground motion is<br />

" s<br />

0.02s and the time duration is 80s, resulting in a total of sampling Fig3.1 3-story shear building<br />

points N=4000. <strong>The</strong> dynamic responses of the building are<br />

computed by the Wilson-0 algorithm and are then taken as the measured responses in the following to<br />

identify both the structural parameters and the ground motion. <strong>The</strong> computed (measured) relative<br />

displacement, velocity and acceleration responses of the top floor are depicted in Fig. 3.2(a) to (c),<br />

respectively.<br />

Time (sec)<br />

Time (sec)<br />

(a) Displacement (b) Velocity (c) Acceleration<br />

Fig.3.2. Computed dynamic responses of the top floor of the building<br />

Noise-free Case<br />

<strong>The</strong> measured dynamic responses without noise contamination are first used to identify the structural<br />

parameters and the* input acceleration ground motion with the dynamic compound inverse method. <strong>The</strong><br />

identification results are summarized in TableS.l, in which the conditions in Cases 1 to 4 are all the