472<br />

investigated a base isolation system in which the isolation mechanism is purely sliding friction. Such<br />

system utilizes pure friction to allow some parts of a structure to slide relative to the others.<br />

A mathematical model was introduced by Qamaruddin [5] and Arya et al. [1] to compute the seismic<br />

response of masonry building with friction base isolation. A new concept has been proposed for the<br />

construction of brick building in which a clear smoothened surface is created just above the dampproof<br />

course at plinth level without any mortar, and the superstructure simply rests at this level and is<br />

free to slide except for frictional resistance. <strong>The</strong> concept of such system was further strengthened by<br />

the damage studies made by Li Li[3] after the Xintai (1966), Bohai(1969) and Tangstan (1976)<br />

earthquakes in which it was found that adobe buildings which were free to slide on their foundations<br />

(by accident) survived with little or no damage whereas others which were tied on their foundations<br />

collapsed. <strong>Research</strong>ers have made experimental and theoretical studies to incorporate such a system in<br />

masonry buildings economically to achieve a collapse free if not a damage free performance during the<br />

earthquakes. Further studies have also been made by Mostaghel et al. [4] and Qamaruddin et al. [6 and<br />

7] with encouraging results.<br />

2. MATHEMATICAL IDEALIZATION<br />

2.1 Mathematical Model<br />

A two-degree spring mass model shown in Fig. 2.1 represents the concept of multistory building with<br />

restricted base sliding. A layer of suitable material of known coefficient of friction is laid between the<br />

contact surfaces of the bond beam of the superstructure and plinth band of the substructure. <strong>The</strong> spring<br />

action in the system is assumed to be provided by the shear walls. Internal damping is represented by a<br />

dashpot that is parallel with the spring. <strong>The</strong> total mass of the superstructure of a multistory building,<br />

i.e., the mass of all the stories, except the bottom half of the ground story is lumped at the top of the<br />

system and the mass of the remaining bottom half portion of the ground story is lumped at the level of<br />

the band beam. <strong>The</strong> lower mass is assumed to rest on a plane with dry frictional damping to permit<br />

sliding of the system. Restricted base sliding can occur at the contact surface without overturning or<br />

tilting. <strong>The</strong> building is subjected to only one horizontal component of ground shaking at a time, the<br />

effect of vertical ground motion is not considered here. <strong>The</strong> stopper is considered as rigid.<br />

2.2 Equations of Motions<br />

Phase I: Initially, bottom mass moves with the base so long as sliding force does not overcome the<br />

frictional resistance. So the building behaves as a single degree of freedom system and therefore<br />

equation of motion is:<br />

M t x t +C s (Z t -Z b )+K s (Z t -Z b ) = 0 (2.1)<br />

orZ t -r2o)^(Z t -Z b )4-03 2 (Z t -Z b ) =-y(t) (2.2)<br />

where, C s = coefficient of the viscous damper; K s = spring constant; M t = top mass; X{, Z{ =<br />

absolute and relative acceleration of the top mass; y(t) = ground acceleration at time t; Z b, Z t =<br />

lateral relative displacement of masses M b and M b respectively; M b - bottom mass; Z b , Zt =<br />

relative velocity of masses M b and M t, respectively; co = natural frequency and £ = fraction of critical<br />

damping.