375<br />

of initialization of structure, modeling uncertainties and so on.<br />

Based on different performance levels according to probability model of earthquake occurrence, the<br />

position of plastic hinges and the sequence of hinge formation are determined. One or some structural<br />

members come to be inelastic to dissipate seismic energy, which should be provided with sufficient<br />

ductility and not occur to spalling damage to resist large infrequent earthquakes. In the other hand,<br />

performance-protected members and others that are inappropriate for dissipation of energy should be<br />

always maintained in elastic response range. Consequently, the action on the columns and beams after<br />

yielding should be paid enough attention to.<br />

EXMAPLE<br />

Model building<br />

Function: Teaching building<br />

Construction site: Design characteristic period of ground motion: 0.40 second.<br />

Building type: Reinforced concrete frame (See Fig 1)<br />

Number of stories: 4 and 6 stories Story height: 3.0m (all stories)<br />

Number of spans: 3 spans Length between spans: 6.0m<br />

<strong>The</strong> cross-section of columns:<br />

450 x 500mm (side column at l~3 rd floor)<br />

500 x 500mm (middle column at l~3 rd floor)<br />

500 x 550mm (side column at 4-6* floor)<br />

550x 550mm (middle column at 4~6th floor)<br />

<strong>The</strong> grade of concrete: C35<br />

<strong>The</strong> cross-section of beams:<br />

Fig 1: Structure mode!<br />

I l l<br />

Fig 2: Plastic hinges formation<br />

Ex. A: 250x 600mm,<br />

Ex. B: 300x 500mm,<br />

Ex. C: 250x600mm(side beams) and 250x500mm(middle beams)<br />

Ex. D: 250x600mm(side beams) and 250x550mm(middle beams)<br />

<strong>The</strong> grade of concrete: C25.<br />

Performance objectives: Slight damage (earthquake probability of occupancy for the 20% in 50 years)<br />

Middle scale damage (the 10% in 50 years)<br />

Performance requirement:<br />

Beam / Column moment: flexural cracks to remain small and no significant spalling should occur<br />

Beam / Column shear: shear failure dose not occur and shear cracks are minor<br />

Mechanism: weak beams / strong column mechanism<br />

Analysis method: the static nonlinear analysis procedure using secant stiffness<br />

Analysis result<br />

Ex. A, B, C, and D is calculated and analyzed, whose position of plastic hinges is shown by Figure.2.