444<br />

each member along or adjacent to the x-axis to which the axial stresses due to the gravity load are<br />

added. It is again observed that the axial stresses of the members of the non-isolated dome are reduced<br />

drastically by introducing the base-isolation system.<br />

Fig. 4.5 shows the hysteresis behavior of the base isolation system. It can be understood that the<br />

present isolation system with sliding mechanism absorbs vibration energies by hysteretic damping.<br />

<strong>The</strong> maximum displacement of the base isolation device remains within 17cm (130% of the height of<br />

isolators) which may be considered allowable. <strong>The</strong> residual displacement of the base isolation device<br />

at the termination of the earthquake remains within 2.4cm due to the effect of laminated rubber<br />

isolators giving restoring forces after sliding.<br />

It can be concluded from the above results that the proposed seismic isolation system is effective in<br />

reducing the dome response under strong earthquake motions.<br />

CONCLUSION<br />

A seismic isolation system with sliding mechanism was proposed for reducing the seismic response of<br />

large-span spatial structures. <strong>The</strong> proposed isolation system is a combination of elastic sliding devices<br />

with commonly used laminated rubber isolators to give restoring forces after sliding. In order to<br />

confirm its effectiveness in reducing the seismic response, shaking table tests were performed using a<br />

small-scale arch model. <strong>The</strong> test results were utilized to validate the simulation method, which was<br />

then applied to investigate the seismic response of a 200m span latticed dome supported by the baseisolation<br />

system. <strong>The</strong> effectiveness of the proposed seismic isolation system was confirmed to reduce<br />

the dome response under strong earthquake motions.<br />

References<br />

Architectural Institute of Japan (1973). Design Standard for Steel Structures, AIJ, Tokyo, Japan.<br />

Architectural Institute of Japan (2001). Recommendation for the Design of Base Isolated Buildings<br />

(2 nd Edition), AIJ, Tokyo, Japan.<br />

Kato, S., Nakazawa, S., Ueki, T., Uchikoshi, M. and Osugi, F. (1998). <strong>Earthquake</strong> response of domes<br />

implemented by hysteresis dampers for earthquake isolation. Lightweight Structures in Architecture,<br />

<strong>Engineering</strong> and Construction, lASS/IEAust/LSAA International Congress, Sydney, Australia, 451-<br />

459.<br />

Kawaguchi, M. and Tatemichi, I. (2000). Seismic isolation systems and their application in space<br />

structures, Bridging Large Spans from Antiquity to the Present, IASS Symposium Istanbul Turkey,<br />

217-228. '<br />

Matsui, M., Qiao, F., Moribe, Y., Sugiyama, E. and Esaka, Y. (2001). Responses of seismically<br />

isolated large span domes to fluctuating wind loads, <strong>The</strong>ory, Design and Realization of Shell and<br />

Spatial Structures, IASS Symposium, Nagoya, Japan, TP120.<br />

Vandier, J.K. et al (1982). A mathematical basis for the random decrement vibration signature analysis<br />

technique, J. Mech, Design 104, 307-313. °