426<br />

by Eqn. 2.9 and Eqn. 2.12, respectively, based on the estimated states obtained by the EKF<br />

4. DAMAGE EVALUATION CRITERIA<br />

In order to compare the performance of various control strategies, some criteria should be given. <strong>The</strong><br />

damage of the hysteretic structures subjected to strong earthquake is the most critical criteria to<br />

evaluate the performance of the structures. Lots of damage evaluation criteria have been given for<br />

hysteretic structures (Cosenza et al 2000). As a whole, the peak value of the interstory drift, the energy<br />

dissipation, and the damage index are the most common criteria to indicate the destroy and collapse of<br />

structures. <strong>The</strong> Park and Ang's damage index will be employed in this study.<br />

In addition, the control force that is related with the power for active control devices will be another<br />

criteria. <strong>The</strong> ratio of the energy dissipation supplied by the control devices to that by the structural<br />

hysteretic characteristics is also a criterion to evaluate the efficiency of the control strategy.<br />

5. NUMERICAL STUDIES<br />

5.1 Full State-Feedback Controller<br />

Consider a 5-story shear building model with active control devices attached at each floor. <strong>The</strong><br />

uniform lumped mass and floor stiffness are 2000kg and 10 6 N/m so that the first period of the linear<br />

structure is 0.99s. <strong>The</strong> critical damping ratio is 0.02 for the first two modes and the Rayleigh damping<br />

matrk keep constant regardless of whether the structure is linear or nonlinear. <strong>The</strong> parameters to<br />

describe the hysteretic characteristics are assumed to be ,4 = 1,a = 0.05,^ = 0.5 and 7 = 0.5. <strong>The</strong> yield<br />

displacement is 2cm, ultimate displacement is 14cm and £ =0 15 used in Park and Ang's damage<br />

index is assumed. <strong>The</strong> control forces in Eqns. 2.12 and 2.5 with the weighing matrix in Eqn. 2.7, and in<br />

Eqn. 2,11 are used in the numerical example, and the additional damping ratio in Eqn. 2.10 is assumed<br />

to be 0.03, 0.08, 0.13 and 0.18. <strong>The</strong> matrix R in Eqn. 2.12 and 2.5 was determined according to the<br />

demand of identical control force for three control strategies. EL Centro, Kobe and Northridge ground<br />

motion records with peak values 3.417m/s 2 , 8.18m/s 2 and 8.27m/s 2 , respectively, are used as inputs.<br />

<strong>The</strong> earthquake intensity is changed by multiplying coefficient ranged from 0.05 to 3.5 for EL Centro<br />

earthquake and 0.05 to 2 for Northridge and Kobe earthquakes with increment 0.1.<br />

<strong>The</strong> interstory drifts of the building subjected to various intensity earthquakes are shown in Fig. 5.1. It<br />

was shown that the response reduction of the first story drift is the nearly same by the three control<br />

strategies, MC, MM and LQR for small and moderate intensity EL Centro, however, the further<br />

reduction for the first story drift was established by the proposed control strategy (MC) than that<br />

achieved by MM and LQR for high intensity EL Centro, Furthermore, the proposed control strategy<br />

(MC) established significant further reduction of the 1 st and 5 th story drifts than MM and LQR by using<br />

the same value of control force for both Northridge and Kobe earthquakes over all intensity range,<br />

especially more significant further reduction established over high intensity range.<br />

Fig. 5.2 show the 1 st floor damage index under Northridge earthquake. <strong>The</strong> results indicate that MC<br />

strategy decreased the damage of the structures more significantly than MM and LQR.