07.05.2015 Views

Pulacayo Project Feasibility Study - Apogee Silver

Pulacayo Project Feasibility Study - Apogee Silver

Pulacayo Project Feasibility Study - Apogee Silver

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Pulacayo</strong> 1 000 t/d Phase I <strong>Feasibility</strong> <strong>Study</strong> - NI 43-101 Technical Report<br />

090644-3-0000-20-IFI-100<br />

Figure 12.43 : Mercator Reject Check Samples - Zn % (N=4)<br />

April 2012 Site Visit Program<br />

During the April 2012 one site visit by Mercator, quarter core samples were obtained from<br />

<strong>Apogee</strong> oxide zone drill core for purposes of independent check sample analysis. In total,<br />

23 quarter core samples were collected to provide sample coverage across the Ag, Pb and<br />

Zn grade ranges represented in the oxide zone. The quarter core samples were collected<br />

from drill holes PUD266, PUD230, PUD220, PUD251 and PUD256 and were submitted for<br />

analysis to SGS del Peru S.A.C.. A sample of certified reference material CDN-SE-1 and a<br />

commercial blank sample were added to the batch of core samples submitted by Mercator for<br />

quality control and quality assurance purposes.<br />

Sample intervals of archived drill core were selected and marked by Mercator and then<br />

photographed prior to being placed in labeled plastic bags for shipment to the laboratory.<br />

Core intervals taken for check sample purposes were clearly identified by explanatory tags<br />

secured in the core boxes for archival reference purposes (Figure 12.44). All core sampling<br />

work was carried out at the <strong>Apogee</strong> core logging facility on the <strong>Pulacayo</strong> property by<br />

Mercator and <strong>Apogee</strong> field staff carried out sample cutting and bagging activities under<br />

Mercator supervision.<br />

After standard crushing and pulverization, Ag, Pb, Zn and Cu levels were determined using<br />

the same preparation and analytical methods that were used in the previous Mercator<br />

program described above.<br />

Mercator core check sample results are compared to original <strong>Apogee</strong> results in Figure 12.45,<br />

Figure 12.46 and Figure 12.47 for Ag, Pb and Zn respectively. Results are interpreted as<br />

showing that acceptable correlation exists between the original oxide zone analyses and the<br />

TWP Sudamérica S.A. Av. Encalada 1257 Of. 801, Santiago de Surco Lima 33, Perú (51-1) 4377473<br />

Page 93

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!