07.05.2015 Views

Pulacayo Project Feasibility Study - Apogee Silver

Pulacayo Project Feasibility Study - Apogee Silver

Pulacayo Project Feasibility Study - Apogee Silver

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Pulacayo</strong> 1 000 t/d Phase I <strong>Feasibility</strong> <strong>Study</strong> - NI 43-101 Technical Report<br />

090644-3-0000-20-IFI-100<br />

Table 13.7 Samples Assays<br />

Sample ID<br />

Grades<br />

Pb, % Zn, % Ag, g/t<br />

Low Grade Composite 0.45 1.32 -<br />

High Grade Composite 2.18 2.7 327<br />

PUD 147 2.72 2.02 375<br />

PUD 093 3.07 4.34 143<br />

PUD 001 4.3 5.96 487<br />

PUD 106 1.52 1.86 136<br />

PUD 146 1.44 2.38 268<br />

PUD 037 2.15 1.63 86<br />

PUD 170 1.65 1.37 139<br />

PUD 203 0.78 0.8 62<br />

PUD 159 1.74 0.81 690<br />

13.8.3 Grindability<br />

Laboratory Rod Milling curves were produced for all the samples to determine the milling<br />

times required to achieve different grinds. This was done by milling 1 kg sample portions for<br />

different time periods. The milled products were wet screened at 53 μm and dry screened at<br />

150 μm, 106 μm, 75 μm and 53 μm.<br />

The main target grind for the flotation tests was d80 75 μm. From this information, the milling<br />

times to achieve this target were determined. The milling times required for the samples<br />

indicated a high degree of variability in hardness between the sample types.<br />

13.8.4 Flotation Experimental Procedures and Results<br />

In total 65 open circuit flotation tests (exploratory test work) were carried out and 4 Locked<br />

Cycle flotation tests. These investigated:<br />

<br />

<br />

<br />

<br />

<br />

Initial Flotation conditions supplied by apogee <strong>Silver</strong> (11 tests)<br />

Initial Variations of known Pb/Zn differential flotation (10 tests)<br />

Differential Pb/Zn sulphide rougher flotation (26 tests)<br />

Pb rougher and cleaner rate flotation tests (10 tests)<br />

Pb and Zn differential cleaner flotation tests (4 tests)<br />

<br />

Pb only cleaner flotation tests (4 tests)<br />

All the flotation products were assayed by XRF. Later, in the test work, the high grade<br />

concentrates were assayed by chemical titration methods, which are more accurate for high<br />

grade products.<br />

TWP Sudamérica S.A. Av. Encalada 1257 Of. 801, Santiago de Surco Lima 33, Perú (51-1) 4377473<br />

Page 110

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!