07.05.2015 Views

Pulacayo Project Feasibility Study - Apogee Silver

Pulacayo Project Feasibility Study - Apogee Silver

Pulacayo Project Feasibility Study - Apogee Silver

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Pulacayo</strong> 1 000 t/d Phase I <strong>Feasibility</strong> <strong>Study</strong> - NI 43-101 Technical Report<br />

090644-3-0000-20-IFI-100<br />

Figure 12.10: Certified Standard Pb128 Results - Pb % (N=91)<br />

The PB138 certified reference material was introduced during the Phase 4 drill program to<br />

replace PB128 and a total of 5 samples of the material were analyzed in association with drill<br />

holes PUD207, PUD210, PUD211A, and PUD214. Ag values returned fell within -9 g/t of the<br />

certified mean value range and average 194.20 g/t, all of which fall within mean ±2 standard<br />

deviations control limits (Figure 12.11). The average Pb value of 1.91% falls within mean ±2<br />

standard deviations control limits, with all but one value falling within -0.25% of the certified<br />

mean range. One value occurs below the lower control limit (Figure 12.12). Zn results fall<br />

within +0.11% and -0.20% of the certified mean value with 2 falling below mean ±2 standard<br />

deviations control limits. The mean value of 2.00% falls within control limits (Figure 12.13).<br />

Based on results presented above, it is apparent that a low bias exists in Ag and Pb results<br />

for CDN-SE-1. This is most pronounced in the Pb data set where 15% of samples returned<br />

values below mean ±2 standard deviations control limits. In contrast, Zn results for CDN-SE-<br />

1 closely track the certified mean value. A low bias may also be present for Ag, Pb and Zn in<br />

the PB138 data set but the limited number of samples (5) prevents further comment. PB128<br />

results for all three metals typically fall within mean ±2 standard deviation project control<br />

limits.<br />

After review of all results, and notwithstanding the possible low bias trends noted above,<br />

Mercator considers combined data of all certified reference material programs by <strong>Apogee</strong> to<br />

be sufficiently consistent to support use of associated datasets for current resource<br />

estimation purposes. However, it is recommended that potential low bias trends be<br />

investigated further.<br />

TWP Sudamérica S.A. Av. Encalada 1257 Of. 801, Santiago de Surco Lima 33, Perú (51-1) 4377473<br />

Page 73

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!