Application Guide<strong>P12x</strong>/<strong>EN</strong> AP/<strong>Eb6</strong>MiCOM P120/P121/P122/P123 Page 7/78The logic associated to the earth fault threshold is identical to the one described above. Thedifferent thresholds I> & tI>, I>> & tI>> and I>>> & tI>>> are respectively replaced bythresholds Ie> & tIe>, Ie>> & tIe>>, Ie>>> & te>>>. and Ie>>>> & tIe>>>>.Thanks to the «Blocking Logic» function, it is possible to freeze the timer as long as the"Block Logic" signal is active.As soon as the blocking “Block Logic" signal disappears, if the overcurrent value is still overthe set threshold, the time delay resumes its countdown considering the value prior to theactivation of the blocking function as its new initial value. This allows a faster clearance ofthe fault after a reset of the “Block Logic" signal.2.1 Instantaneous function (50/50N) (P122 and P123 relays)In order to ensure fast tripping on highly saturated current signal, it has been decided thatI>>> and Ie>>> should operate on a current sample base in addition to the Discrete Fouriertransformation bases (see User Guide chapter). Both algorithms can operate on a highlysaturated current signal. However with a high X/R ratio, it is recommended to use the samplebase method.As soon as a phase (or earth) threshold is running, the instantaneous output associated withthis threshold is activated. This output indicates that the protection element has detected aphase (or earth) fault and that the time delay associated with the threshold has started. Thistime delay can be blocked via the logic input "Block Logic" associated with this threshold. Ifthis blocking input is activated by an output contact of a downstream relay, the logic that willlead to the trip command is then blocked only if the relay that is the closest to the fault cansee and therefore eliminate the fault. This principle is known as «Blocking logic» or«Blocking». It is described in more detail in this document.2.2 Derived earth overcurrent threshold (Ie>>>>, P122 and P123 only)The derived earth current (Ie>>>>) is the vectorial summation: IA + IB + IC :IA + IB + IC = Ie>>>>.The Ie>>>> can be set as definite delay time or inverse delay time using the IEC,IEEE/ANSI, CO, RI and RECT curves. Their parameters are shown in the Technical Datachapter of this Technical Guide.P3940<strong>EN</strong>aIAIBICIA+IB+IC = Ie>>>>Ie = Tank EarthAs soon as Ie>>>> threshold is running, the instantaneous output associated with thisthreshold is activated. This output indicates that the protection element has detected anearth fault and that the time delay associated with the threshold has started. This time delaycan be blocked via the logic input "Block Logic" associated with this threshold. If this blockinginput is activated by an output contact of a downstream relay, the logic that will lead to thetrip command is then blocked only if the relay that is the closest to the fault can see andtherefore eliminate the fault. This principle is known as «Blocking logic» or «Blocking». It isdescribed in more detail in this document.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!