P12x/EN T/Eb6 - Schneider - error

P12x/EN T/Eb6 - Schneider - error

P12x/EN T/Eb6 - Schneider - error

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Communications<strong>P12x</strong>/<strong>EN</strong> CT/<strong>Eb6</strong>DNP 3.0 DatabaseMiCOM P120/P121/P122/P123 Page 111.4.2 Binary Output Status Points and Control Relay Output BlocksThe following table lists both the Binary Output Status Points (Object 10) and the ControlRelay Output Blocks (Object 12). Binary Output Status points are not included in class 0polls.Binary Output Status PointsObject Number: 10Request Function Codes supported:1 (read)Default Variation reported when variation 0 requested: 2 (Binary Output Status)Control Relay Output BlocksObject Number: 12Request Function Codes supported:P120PointIndexP121PointIndexP122PointIndexP123PointIndex3 (select), 4 (operate),5 (direct operate), 6 (direct operate, noack)Name/DescriptionInitial StatusValueSupported ControlRelay Output BlockFields0 0 0 0 De Latch of relays 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On1 1 1 1 Acknowledgement of the 1 st alarm 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On2 2 2 2 Acknowledgement of all the alarms 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On3 3 3 3 Remote control Triping 0 Unpaired Pulse On,Paired Trip/Pulse On,4 4 4 4 Remote control Closing 0 Unpaired Pulse On,Paired Close/Pulse On5 5 Change of Active Group 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On6 6 Thermal State Resetting 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On7 7 Average and Max rms values resetting 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On8 8 Acknowledgement of RAMs material alarms 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On9 Counters initialization of the autorelosure 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On9 10 Initialization of rolling demand (average) 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On10 11 Initialization of Maximum 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On12 Re initialization of autoreclosure 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On11 13 tc com1 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On12 14 tc com2 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On13 15 tc com3 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On14 16 tc com4 0 Unpaired Pulse On,Paired Trip/Pulse On,Paired Close/Pulse On

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!