Communications<strong>P12x</strong>/<strong>EN</strong> CT/<strong>Eb6</strong>MODBUS DatabaseMiCOM P120/P121/P122/P123 Page 15Address Group DescriptionValuesrangeStep Unit FormatFaultValueRange0190 Disturbance Pre-time 1 to 291 to 361 to 491 to 741 to 1491 1/10 s F1 1 P122-P1230191 Do not use0192 Disturbance starting condition 0 - 1 1 F32 0 P122-P1230193 CB supervision Operating time supervision 0 - 1 1 F24 0 P122-P1230194 Operating time threshold 5 to 100 5 1/100 s F1 5 P122-P1230195 Operations number supervision 0 - 1 1 F24 0 P122-P1230196 Operations number threshold 0 - 50000 1 F1 0 P122-P1230197 CB switched Amps sumsupervision (Power n)0198 CB switched Amps sumthreshold0 - 1 1 F24 0 P122-P1230 to 4000 10E6 An P122-P1230199 Amps or square Amps 1 - 2 1 F1 1 P122-P123019A Closing time threshold 5 to 100 5 1/100 s F1 0 P122-P123019B Aux inputs Auxiliary timer 1 0 to 20000 1 1/100 s F1 0 P120 to P123019C Auxiliary timer 2 0 to 20000 1 1/100 s F1 0 P120 to P123019DMax. & averagemeasurementPeak value 5 to 60 min F42 5 P122-P123019E Broken conductor I2 / I1 threshold 20 to 100 1 % F1 20 P122-P123019F CB supervision Tripping time 10 to 500 5 1/100 s F1 10 P122-P12301A0 Closing time 10 to 500 5 1/100 s F1 10 P122-P12301A1Closing time thresholdsupervision0 - 1 1 F24 0 P122-P12301A2 CB Fail Trip circuit supervision 0 - 1 1 F24 0 P122-P12301A3 t SUP 10 to 1000 5 1/100 s F1 10 P122-P12301A4 I< threshold CB failure 10 - 100 1 %In F1 10 P122-P12301A501A6Instantaneous phase blocking ifCB failureInstantaneous earth blocking ifCB failure0 – 1 1 F24 0 P122-P1230 – 1 1 F24 0 P122-P12301A7 Rolling Demand Sub period 0 – 60 1 min F1 P122-P12301A8 Sub period number 0 – 24 1 F1 P122-P12301A9Output relaysallocationCommunication Order 1 0 - 31 1 F14 0 P122-P12301AA Communication Order 2 0 - 31 1 F14 0 P122-P12301AB Communication Order 3 0 - 31 1 F14 0 P122-P12301AC Communication Order 4 0 - 31 1 F14 0 P122-P12301AD T comm 1 10 – 60000 5 1/100s F1 10 P122-P12301AE T comm 2 10 – 60000 5 1/100s F1 10 P122-P12301AF T comm 3 10 – 60000 5 1/100s F1 10 P122-P12301B0 T comm 4 10 – 60000 5 1/100s F1 10 P122-P12301B1 tAux3 0 – 31 1 F14 0 P122-P12301B2 tAux4 0 – 31 1 F14 0 P12301B3 Auxiliary timer3 0 – 20000 1 1/100s F1 0 P122-P12301B4 Auxiliary timer4 0 – 20000 1 1/100s F1 0 P12301B5 – 01BC Courier Courier Description 32-127 1 F10 P1 P120 to P123

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!